Pin assignment of the IndraControl VAC 30.1 connection module
NOTICE
Use only copper wire for wiring the connection terminals. Tighten the screws
of the screw terminals with a torque of 2.25 lb in (0.22 Nm).
DANGER
For safety reasons, the voltage supply for the connection module (X1.1 pin1,
X1.2 pin1) must be monitored. If the voltage fails, the stop pushbutton at the
device is inoperative.
The IndraControl VAC 30.2 connection module including automatic stop
pushbutton jumpering is supplied with voltage via X1.1 pin1 or X1.2 pin1. The
connected hand-held terminal is supplied with voltage via X1.1 pin3 or X1.2
pin3. To make the hand-held terminal engageable or disengageable when it
is plugged-on, the wire jumper between X1.2 pin1 and X1.2 pin3 is to be re‐
moved and the switching voltage for the hand-held terminal is to be applied to
X1.1 pin3 or X1.2 pin3.
In contrast to the IndraControl VAC 30.2, the previous variant IndraControl
VAC 30.1 was neither equipped with a separated voltage supply nor with a
signal contact. The pins 4 and 3 of the terminal blocks X1.1 and X1.2 are not
available on the IndraControl VAC 30.1. All existing pins of the VAC 30.1
connection module are compatible with the IndraControl VAC 30.2 pins.
Bosch Rexroth AG
Pin Assignments of the IndraControl VEH 30.2
Signal name
DC 24 V connection module
0 V
DC 24 V terminal
DC 24 V connection module
0 V
DC 24 V terminal
Terminal connected IN
Terminal connected OUT
Stop pushbutton 1 IN
Stop pushbutton 1 OUT
Stop pushbutton 2 IN
Stop pushbutton 2 OUT
Enabling device 1 IN
Enabling device 1 OUT
Enabling device 2 IN
Enabling device 2 OUT
Destruction of screw terminals, insufficient
contact and loss of UL certificiation if inad‐
quate wire is used and/or wrong tightening
torque.
Risk of injury caused by voltage loss and
non-functioning stop button!