Digalox DPM72-PP Instruction manual (Rev-2018-09)
Visit www.digalox.com to download the software "Digalox Manager".
Package contents: Panel meter Digalox DPM72, 5 × jumpers, 1 × mounting bracket
1. Intended Use
Indoor use non condensing, non corrosive.
Panel mounting.
Failure to comply with these instructions will void all guarantee and warranty.
In operation, supply the device preferably via screw terminals with 10 to 24 V
AC/DC. If the device is supplied via USB in operation, USB supply voltage must
be at least 5 V.
2. Safety instructions
Note: The measurement inputs of the device can carry life-threatening
voltages!
When working on the device hazardous voltages must not be connected to
the device!
The device must not be used as the only protective device or protective
shutdown.
Read instruction manual carefully before operating the device!
The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).
When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 250 V AC switches must be isolated for
at least 500 V.
Do not open the housing!
Do not use the instrument in the presence of explosive or flammable substances!
All cables carrying hazardous voltages must be secured with external separators.
----- 1 -----

Advertisement

loading

Summary of Contents for TDE Instruments Digalox DPM72-PP

  • Page 1 Digalox DPM72-PP Instruction manual (Rev-2018-09) Visit www.digalox.com to download the software “Digalox Manager”. Package contents: Panel meter Digalox DPM72, 5 × jumpers, 1 × mounting bracket 1. Intended Use  Indoor use non condensing, non corrosive.  Panel mounting. ...
  • Page 2 3. Description The measurement modes analogue signal and AC/DC shunt are supported. Minimum and maximum values are recorded and can be displayed optionally using an external switch. Measured values are recorded over a time span of three minutes up to 14 days. The time base as well as the display of the measure history can be activated by an external switch.
  • Page 3 4. Electrical Connections Supply 20 mA analogue signal 10 - 24 V Fuse 250 mA high high max. − Digalox Supply Current measurement with shunt Current measurement with shunt on high side, max. 50 V! high high high high max. Load Shunt Shunt...
  • Page 4 5. Configuration The device can be configured via DIP switches and jumpers manually or with the corresponding software “Digalox Manager” via USB interface. When configuring via DIP switches and jumpers the basic settings can be made computer-independent. The configuration with the software “Digalox Manager” allows full functionality. Scaling In modes where a scaling is necessary to represent the correct measurement value (for example 60 mV DC for shunt or analogue signal) the upper scale value...
  • Page 5 Configuration via DIP switches and jumpers if it is required to switch between multiple measurement modes via an external switch (Save mode) The required measurement modes are configured and saved sequentially. 1. Connect supply voltage. 2. Set DIP-switch 10, 11 and 12 to OFF position. 3.
  • Page 6: Measurement Display

    Table common switch combinations Value Combination Value Combination (DIP switch 1-9) (DIP switch 1-9) 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12...
  • Page 7 6. Other settings The following functions can be activated independently by short-circuiting connectors J1-J3 by jumper or switch during operation: J1: Graphical historic data display To activate the graphical historic data display connector J1 is shorted. The unit displays the stored values within the set time base as a graphical trend.
  • Page 8 9. Cleaning Observe the safety instructions before cleaning the instrument. Clean the instrument with a dry lint-free soft cloth. Do not use solvents. 10. Contact Information TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn phone: +49 7157-20801 E-Mail: info@tde-instruments.de Internet: www.tde-instruments.de, www.digalox.com...