TDE Instruments Digalox DPM72-PP Instruction Manual
Hide thumbs Also See for Digalox DPM72-PP:

Advertisement

Quick Links

Digalox
®
DPM72-PP Instruction manual (Rev-2021-07)
Visit www.digalox.com to download the software "Digalox
Package contents:
1. Intended Use
Indoor use non condensing, non corrosive.
Panel mounting.
Failure to comply with these instructions will void all guarantee and warranty.
In operation, supply the device preferably via screw terminals with 12 to 24 V
AC/DC instead of via USB.
2. Safety instructions
Note: The measurement inputs of the device can carry life-threatening
voltages!
When working on the device hazardous voltages must not be connected to
the device!
The device must not be used as the only protective device or protective
shutdown.
Read instruction manual carefully before operating the device!
The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).
When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 10 V switches must be isolated for at
least 20 V.
Do not open the housing!
Do not use the device in the presence of explosive or flammable substances!
All cables carrying hazardous voltages must be secured with external separators.
Panel meter Digalox
5 jumpers, 2 instruction manuals (EN + DE)
----- 1 -----
®
Manager".
®
DPM72-PP, mounting bracket,

Advertisement

loading

Summary of Contents for TDE Instruments Digalox DPM72-PP

  • Page 1 Digalox ® DPM72-PP Instruction manual (Rev-2021-07) ® Visit www.digalox.com to download the software “Digalox Manager”. Package contents: Panel meter Digalox ® DPM72-PP, mounting bracket, 5 jumpers, 2 instruction manuals (EN + DE) 1. Intended Use Indoor use non condensing, non corrosive. ...
  • Page 2 3. Description The measurement types analogue signal and AC/DC shunt are supported. Minimum and maximum values are recorded and can be displayed optionally using an external switch. Measured values are recorded over a time span of 36 seconds up to 14 days.
  • Page 3 4. Electrical Connections Supply (Digalox) 20 mA analogue signal Digalox 12 - 24 V Fuse 250 mA high high max. − 100 mA Digalox Supply Current measurement with shunt Current measurement with shunt on high side, U < 50 V! Digalox Digalox high...
  • Page 4 5. Configuration The device can be configured via DIP switches and jumpers manually or with the corresponding software “Digalox ® Manager” via USB interface. When configuring via DIP switches and jumpers the basic settings can be made computer-independent. The configuration with the software “Digalox ®...
  • Page 5 Configuration of display values via DIP switches and jumpers if it is required to switch between multiple display values via an external switch (Save mode) The required display values are configured and saved sequentially. 1. Set DIP-switch 10, 11 and 12 to OFF position. 2.
  • Page 6 Table common switch combinations (DIP switch 1-9) Value Combination Value Combination 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2...
  • Page 7 6. Other settings The following functions can be activated independently by short-circuiting connectors J1-J3 by jumper or switch during operation: J1: Graphical historic data display The unit displays the stored values within the set time base as a graphical trend. The time base can be set to days (7, 14), hours (1, 3, 6, 12, 24, 48, 72), minutes (3, 15, 30) or seconds (36).
  • Page 8 9. Cleaning Observe the safety instructions before cleaning the device. Clean the device with a dry lint-free soft cloth. Do not use solvents. 10. Contact Information TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn phone: +49 7157-20801 E-mail: info@tde-instruments.de Internet: www.tde-instruments.de, www.digalox.com...