Download Print this page

TDE Instruments Digalox DPM72-MPP Instruction Manual

Advertisement

Quick Links

Package contents:
1. Safety instructions
• Read instruction manual carefully before operating the device! Keep for later
reference.
• Mounting and installation must be carried out by suitably qualified and competent
persons only.
• When working on the device hazardous voltages must not be connected to
the device! The terminals J1-J12 are not isolated from the measuring
circuit.
• The device must not be used as the only protective device or protective
shutdown.
• The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).
• When connecting switches to the terminals J1-J8, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 30 V DC switches must be isolated for at
least 60 V.
• Do not open the housing!
• Do not use the device in the presence of explosive or flammable substances!
• All cables carrying hazardous voltages must be secured with external separators.
2. Meaning of symbols
General warning sign
(Attention, observe the documentation!)
Warning of an electrical hazard
Digalox
Instruction manual (Rev-2021-07)
Graphical panel meter with RGB backlight
for analogue signal 0/2 - 10 V and 0/4 - 20 mA
Panel meter Digalox
5 jumpers, 2 instruction manuals (EN + DE)
®
DPM72-MPP
®
DPM72-MPP, mounting bracket,
----- 1 / 8 -----

Advertisement

loading

Summary of Contents for TDE Instruments Digalox DPM72-MPP

  • Page 1 ® Digalox DPM72-MPP Instruction manual (Rev-2021-07) Graphical panel meter with RGB backlight for analogue signal 0/2 - 10 V and 0/4 - 20 mA Package contents: Panel meter Digalox ® DPM72-MPP, mounting bracket, 5 jumpers, 2 instruction manuals (EN + DE) 1.
  • Page 2 3. Intended use • Measurement of current and voltage in the specified measuring ranges for process signals • Indoor use non condensing, non corrosive. • Panel mounting. • In operation, supply the device preferably via screw terminals with 12 to 24 V AC/DC instead of via USB.
  • Page 3 12 - 24 V Outputs max. historic data display, min/max 30 V 50 mA display, auto-scaling, display value (mode), ... Digalox DPM72-MPP www.digalox.com Made in Germany 3 Supply voltage input 4 Interface (USB Micro-B / XBEE / RS485) high high 100 mA max.
  • Page 4 7. Electrical connections Supply (Digalox) 10 V analogue signal Digalox 12 - 24 V Fuse 250 mA high high max. − 30 V Digalox Supply 20 mA analogue signal 20 mA and 10 V analogue signal Digalox Digalox high high high high max.
  • Page 5 8. Configuration Connect the device to a computer: USB: Connect the device and the computer using a USB cable. The device driver is installed automatically if the computer is connected to the Internet. XBEE: Insert the XBEE stick into the computer. The device driver is installed automatically if the computer is connected to the Internet.
  • Page 6 9. Other settings The following functions can be activated independently during operation by short- circuiting connectors J1-J3, e.g. using a jumper or switch: J1: Graphical historic data display The unit displays the stored values within the set time base as a graphical trend. The time base can be set to days (7, 14), hours (1, 3, 6, 12, 24, 48, 72), minutes (3, 15, 30) or seconds (36).
  • Page 7: Specification

    10. Maintenance Periodically check all external cable connections. 11. Cleaning Observe the safety instructions before cleaning the device. Clean the device with a dry lint-free soft cloth. Do not use solvents. 12. Specification DPM72-MPP 12 - 24 V AC/DC ±10% (50/60 Hz ±10%) or if Supply applicable via USB, galvanically isolated Power consumption...
  • Page 8 77.5 68.0 Panel cut-out 72.0 73.5 14. Available accessories ® TDE Instruments Digalox DPM72 gasket EPDM/SBR 15. Contact information TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn Phone: +49 7157 20801 E-mail: info@tde-instruments.de Internet: www.tde-instruments.de, www.digalox.com ----- 8 / 8 -----...

This manual is also suitable for: