AMULET REPLACEMENT
It is recommended that a new ceramic sleeve "amulet" be installed each time the air tube is removed from unit.
See instructions that come with each amulet. The Frontier amulet is larger than the standard amulet, so be sure to
order the proper part number shown in the Assembly Drawing. Using a standard amulet will allow excessive heat
back to the front jacket and may damage burner tube.
FLAME FORMER REPLACEMENT
The flame former is of high quality refractory ceramic fiber material and will normally not need to be replaced. A
replacement, if required, is available from Energy Kinetics. Ensure that the burner head is protected by the amulet, wet
pack or a similar material.
CAUTION: A dust mask must be worn during replacement:
WARNING: Ceramic fiber or fiberglass materials, may contain carcinogenic particles (cristobalite) after exposure to heat.
Airborne particles from fiberglass or ceramic fiber components have been listed as having potential health effects. Take
the following precautions when removing, replacing and handling these items.
Precautionary procedures:
Avoid breathing dust and avoid contact with skin or eyes. Wear long-sleeved, loose-fitting clothing, gloves and eye
protection. Use a properly fitted NIOSH certified respirator for dusty activities and where exposure levels are unknown.
Use hand tools whenever possible if cutting or trimming is required. Power tools generate significantly more airborne
dust.
Use vacuums with HEPA-filters for clean up. If HEPA-filter vacuum are not feasible, lightly spray fiber materials and
work area with a water mist before sweeping or bagging of debris.
Wash exposed skin with soap and water after handling.
Do not use compressed air to clean work clothes or work area.
Wash work clothes separately from other clothing. Rinse washer thoroughly afterwards.
Avoid smoking, eating or drinking while dust is present in the work area.
REPLACEMENT PARTS
Obtain replacement parts from your local Energy Kinetics dealer.
Contact Energy Kinetics at 800-323-2066 Or
Part Number
10-0494-3
10-0494-G
10-0536
10-0760
10-0761
10-0762
10-0763
10-0764
10-0765
10-0766
10-0767
10-0768
10-0769
10-0770
EK3 Frontier Boiler Manual
www.energykinetics.com
AIRBOX KIT FOR EK3 FRONTIER, NO INLET SCREEN
AIRBOX KIT, EK3 GAS, FLANGE MOUNT, NO INLET SCREEN
EK3 BOILER STAND
EK3 HALF CHAMBER FLAME FORMER
EK3 FRONTIER FRONT DOOR
EK3 FRONT PACMAN
EK3 REAR PACMAN
EK3 LEFT SIDE COVER
EK3 FRONT INSULATION BD
EK3 REAR INSULATION BOARD
EK3 RIGHT SIDE COVER
EK3 TOP COVER
EK3 REAR COVER
EK3 PUFF SWITCH KIT
24