Specifications; General Specifications - Leuze electronic MA 204i Technical Description

Modular interfacing unit for leuze ident and rs 232 devices on profibus dp
Table of Contents

Advertisement

5

Specifications

5.1

General specifications

Electrical data
Interface type 1
Interface type 2
Service interface
Switching input/output
Operating voltage
Power consumption
Max stress on the connector
(PWR IN/OUT)
Indicators
COM LED
PWR LED
Mechanical data
Protection class
Weight
Dimensions (W x H x D)
Housing
Connection
Environmental data
Operating temperature range
Storage temperature range
Air humidity
Leuze electronic
PROFIBUS DP,
BUS:
PWR/IO: 1x M 12 connector (A-coded),
Protocols PROFIBUS DP-V0
Baud rate 9.6 kBd ... 12 MBd
RS 232
Baud rate 300 bit/s ... 115200 bit/s, default: 9600
RS 232, 9-pin Sub-D connector, Leuze standard
Data format data bit: 8, parity: None, stop bit: 1
1 switching input/1 switching output
device-dependent voltage
18 ... 30 V DC
max. 5VA (without DEV, current consumption
max. 300 mA)
3 A
green
Bus state ok
red
Bus error
green
Power
red
Collection error
IP 65 (with screwed-on M12 and connected Leuze device)
700 g
130 x 90 x 41 mm / with plate: 180 x 108 x 41 mm
diecast aluminum
2 x M 12: BUS IN / BUS OUT PROFIBUS DP
1 connector: RS 232
1 x M12: Power IN/GND and switching input/output
1 x M12: Power OUT/GND and switching input/output
0 °C ... +55 °C
-20 °C ... +60 °C
max. 90 % rel. humidity, non-condensing
1x M 12 connector (B-coded),
1x M 12 socket (B-coded)
1x M 12 socket (A-coded)
MA
204i
Specifications
21

Advertisement

Table of Contents
loading

Table of Contents