Insert the filter fully on the intake valve
Fasten the clip.
Replace panels PS and PF of the
compressor cabinet
To reset the scheduled maintenance counter (for enabled users only), see paragraph 7.4.2.2.
GENESIS - FORMULA - MODULO 15 kW / 20 hp (BA 69)
GENESIS - FORMULA:
Open the corner panel SPA of the com-
pressor cabinet using the key provided
G
MODULO:
B
Open the filter panel SF of the compres-
sor cabinet using the key provided
Release the front part of the filter con-
tainer CF pressing on the two fastening
tabs (Fig. 39)
Remove air filter FA from its housing as
shown in Fig. 40
Clean the filter by directing a jet of air
inside it or replace the filter as pre-
scribed in the maintenance schedule.
Do not use fluids or detergents to clean
the filter
Replace filter FA inserting it fully
Re-attach the front part of the filter con-
tainer CF pressing on the two fastening
tabs
GENESIS - FORMULA:
Replace the corner panel SPA of the
compressor cabinet
MODULO:
Replace the filter panel SF of the com-
pressor cabinet
To reset the scheduled maintenance counter (for enabled users only), see paragraph 7.4.2.2.