Lubricated rotary screw compressor 5.5 - 15 kw
Table of Contents

Advertisement

Disconnect the power supply, vent the air and wait for the machine to cool before performing
any operation or removing the guards
After disconnecting the power, lock out the circuit breaker to prevent accidental start-up
while operating on the compressor. Additionally, close the shut-off valve between the com-
pressor and the line
All the air has been discharged from the machine when pressure gauge MPI shows zero
pressure
No changes must be made to machine internal electrical, pneumatic, hydraulic circuits and/or to the set-
tings. In particular, do not modify the maximum working pressure values and the valve settings, especially
the safety valves.
Do not use solvents, flammable or toxic fluids to clean the machine parts. Use alkaline detergents only. Never
use detergents to clean the motor or the electrical/electronic components.
Do not weld or carry out mechanical machining operations on the receivers. If damaged or rusted, replace
the parts, as they are subject to specific safety regulations.
At the end of each operation, refit the guards carefully. Comply with the same precautions for initial start-
up.
Remember that waste oil, condense and machine filters are polluting materials. Dispose of
these products in compliance with local legislation
P. 29 - Chap 5 Safety precautions