Draining the condensate

Before performing any maintenance operations read the operator safety precautions in
chapter 5 carefully. These precautions must be followed scrupulously for all maintenance
operations
If the machine is equipped with dryer and/or air reservoir, the mc
activation of the solenoid valve of the condensate drain.
On machines equipped with dryer, with or without air reservoir, condensate drainage can be checked using
the sleeve located on the rear panel PP
On machines equipped with air reservoir, condensate drainage is checked using the solenoid valve located
underneath the air reservoir SA
Air receiver
G
To eliminate the condensate that forms in the air receiver, proceed as follows:
B
Place a suitable drip tray under the
condensate discharge valve RSC,
which is located under the SA
receiver
Ensure that the intercept valve between
the compressor and the distribution line
is closed
Open the condensate discharge valve
RSC (fig. 47), using pliers if necessary
Leave the condensate to drain until the
tank is completely empty
Close the valve RSC
Remember that waste oil, condensate and all machine filters are polluting materials that must
be disposed of in compliance with local legislation
Fig. 47
P. 76 - Chap. 10 Maintenance