ABAC GENESIS Series Use And Maintenance Handbook page 72

Lubricated rotary screw compressor 5.5 - 15 kw
Table of Contents

Advertisement

Operation
Overhaul minimum
pressure valve
Overhaul
intake valve
Replace
oil filter
Check - top up
oil level
Change
oil
Replace
G
separator filter
B
Check
oil recovery system
Check
fitting tightness
-
Check
electrical terminal
connections
Drain
air-oil receiver
condensate
Clean
radiators
Clean
dryer condenser
Replace
air dryer filters
Check
belt tension and wear
Replace
drive belts
Check
settings and
adjustments
Check
safety device
operation
*
This frequency relates to operation in normally dust environments. In the case of critically dust
environments, the control panel may signal the need to replace the air filter before the scheduled maintenance
time. In this case, replace the filter as soon as possible. The skilled personnel employed for installation will
be able to objectively evaluate the environmental conditions
To be carried
Reference
out by a
Service Centre
10.6
10.5
10.5
10.6
10.7
P. 70 - Chap. 10 Maintenance
After the
After the
Every
first
first
500
100 hours
1000 hours
hours
Every
Every
Every
1000
2000
4000
hours
hours
hours

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Modulo seriesFormula series

Table of Contents