ABAC GENESIS Series Use And Maintenance Handbook page 61

Lubricated rotary screw compressor 5.5 - 15 kw
Table of Contents

Advertisement

Messages of this type are as follows:
Replace air filter
-
-
Replace oil filter
-
Replace oil
-
Replace separator filter
-
Replace air filter - excess. clogging
for this last fault, after replacing the filter, press the K3 - RESET key
2)
For critical operating condition messages:
If possible eliminate the problem; the message will be cleared automatically
Messages of this type are as follows:
-
Compression temp. high
-
Ambient temperature low
WARNING!!!
If the warnings are not reset for a long period of time (e.g. failure to carry out scheduled
maintenance) THE COMPRESSOR IS BLOCKED!!! In this case, contact the Service or
Customer Centre of the Manufacturer immediately.
Alarm messages
These messages indicate a serious fault that has blocked the compressor. The alarm may be due to a
fault in the system or extremely critical operating conditions.
When a machine stoppage occurs, the compressor stops immediately, the red LED L3 of the alarms
switches on and the message relating to the fault is displayed persistently in the main screen page.
To RESET, first of all eliminate the fault: at this point, LED L3 starts to flash indicating that reset
can be carried out pressing the RESET key.
P. 59 - Chap. 7 Start-up and operation