Figure 19
Legend:
1 Pump and air separator
2 Pressure gauge
3 Heating circuit extractable filter
4 Boiler filling tap
5 Check valve on automatic by-pass
6 Water pressure switch
7 Boiler drain tap
8 Safety valve
9 Gas valve
10 Gas train with injectors
11 Central heating NTC sensor
INSTRUCTIONS FOR FITTERS
Heating
Gas
delivery
12 Ignition / flame detection electrode
13 Safety thermostat
14 Water-fumes exchanger
15 Fumes conveyor
16 Fan
17 Venturi tube
18 Positive pressure point
19 Negative pressure point
20 Air pressure switch
21 Burner
22 Expansion vessel
29
&
DHW
Heating
inlet
return
7222863.02 - en