Summary of Contents for Baxi ECO3 COMPACT

  • Page 1 WALL HUNG GAS BOILERS Technical Training Course Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 2: Range Of Models

    1.140 i Range of models Open flue - 14 kW of heat output • ECO 1.140 Fi Fanned flue – 14 kW of heat output • ECO 1.240 i Open flue - 24 kW of heat output • ECO 1.240 Fi Fanned flue –...
  • Page 3  Compactness : the ultimate in space saving! BAXI introduced in its product range ECO , a gas wall hung boiler distinguished by the compact dimensions: the real innovation lies in the maximum space saving ensured considering the boiler installed.
  • Page 4: Lcd Display

     LCD display is provided with a full information LCD display: a wide section where you can easily check all the main data related to the boiler working. Functions and anomalies are displayed not only by codes but in particular by immediate symbols. This makes the information clear and prompt! Documento riservato –...
  • Page 5  Reliability and easiness of use is the result of the great combination of high reliable components and a meticulous choice of all the materials used. To make an example, the gas and combustion groups have already been tested in three years of production (more than 100.000 boilers manufactured), and the hydraulic group is the evolution of the existing group present in other models of WHB range.
  • Page 6 ECO 3 Compact Vacuum pack Control panel display LCD DHW exchanger Plate exchanger Versions NTC sensor Range of Temperature Grade of protection IPx4D Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 7 Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 8: General Features

    General features Two separate heat exchangers: primary exchanger made of copper pipes, covered with aluminium-silicon paint to increase its heat resistance. Stainless steel plates exchanger for DHW production.  New hydraulic group with integrated electric three way valve (combination models), automatic by-pass, pump with automatic air vent, filling tap and relief valve.
  • Page 9 A broad views LCD display: clear and prompt information • Burner lighted • Gas problems • CH operation • DHW operation • CH water temperature • CH-DHW set temperature • Anomaly codes • Anomaly • Lack of water general warning •...
  • Page 10: Safety Device Indicators - Activation

    Safety device indicators - activation If a fault occurs, the display reads out an error message identifying it (es. E 10): Resetting errors To RESET the gas boiler, turn selector (Figure 2) to “R” for at least 2 seconds. If the fault persists, call an authorised service centre.
  • Page 11 Safety device indicators - activation Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 12 DISPLAY –“INFO” mode IMPORTANT : the following operations, it has to be carried out in fast sequence in a short time (~ 4 seconds) without making any break during the steps: 1) with the control knob ( ) in any position turns it fully anti-clockwise to the minimum value; 2) quickly turn control knob clockwise through about a 1/4 turn;...
  • Page 13 DISPLAY –“INFO” mode Turn the control knob to dispay the following informations: A00 Real DHW temperature A01 Real external temperature A02 Modulating current % (with N.G. = 30-230 mA dc; with LPG = 45-310 mA A03 Boiler Output % A04 CH set-point temperature A05 Real CH temperature A07 Flame signal % (the ionisation signal normally is more than 2 microA)
  • Page 14: Control And Operation Devices

    Control and operation devices Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 15 Control and operation devices Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 16 Control and operation devices Overheat safety thermostat : 105°C SONDE NTC HONEYWELL SO11001 Flue thermostat:70°C Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 17 NTC Sensors The boiler has 2 NTC sensors: - one for Central Heating Circuit - one for DHW circuit Sensors are interchangeable. In case of failure of the DHW sensor, the boiler operates only in Central Heating. 1. Sensor Body 2. Electrical Connection Beta = 3435 Temperature Resistance (±1%)
  • Page 18 •BERTELLI (not polarized) •HONEYWELL (polarized) operation of the boiler with LPG operation of the boiler with NATURAL gas T.Risc boiler heating temperature range 30 - 45°C T.Risc boiler heating temperature range 30 - 85°C T-off 30-seconds heating stand-by time T-off 150-seconds heating stand-by time Documento riservato –...
  • Page 19 P.C.B. 240 Fi Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 20 P.C.B. 240 i Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 21 New compact hydraulic group  Entirely made of brass, to assure reliability and long life.  DHW stainless steel plates exchanger: its high exchange power is a guarantee of great comfort: up to 13,7 litre per minute at steady temperature. ...
  • Page 22 Heat exchanger “VALMEX” - 24 Kw - Safety thermostat: 105°C Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 23 GAS VALVE P. min P. max for open flue and fanned flue SIT SIGMA 845063 Burner gas pressure Inlet gas pressure COILS ELECTRIC SUPPLY: 230 V ac (Electric coils connected in parallel) Max.supply gas pressure: 60 mbar MODULATOR ELECTRIC FEATURES : Code: 5658830 - Modulating Coil Ohmic Resistance: 20 Ohm (T=25°C) - Voltage to the Modulator:...
  • Page 24: Gas Valve Adjustments

    Gas valve adjustments Adjustment of Nominal Output (P.max) • Connect the positive pressure intake of a differential manometer to the gas valve pressure intake (Pb). • Connect the negative pressure intake of the manometer to a “T” fitting in order to join the boiler compensation intake, the gas valve compensation intake (Pc) and the manometer.
  • Page 25 Gas valve adjustments Adjustment of the reduced output (P.min) • Disconnect a modulator wire and adjust the red screw to reach the pressure value as specified in the instruction manual if the boiler. • Connect the cable again. • Fit the modulator cover and seal its fixing screw. Documento riservato –...
  • Page 26 GAS VALVE for open flue and fanned flue P. max P. min HONEYWELL VK 4105 M GAS VALVE Burner gas ELECTRIC SUPPLY: 230 Vrac pressure (rectified) (Electric coils connected in parallel) Inlet gas pressure Max.supply gas pressure: 60 mbar MODULATOR ELECTRIC FEATURES : - Modulating Coil Ohmic Resistance: 40 Ohm (T=25°C) - Voltage to the Modulator:...
  • Page 27 HONEYWELL VK 4105 M This valve is alternative to Sit Sigma 845063 Valves interchangeable and same adjustment system. Plastic cap Modulator’s wires Maximum output adjusting nut Reduced output adjusting nut Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 28 Gas valve adjustments Adjustment of Nominal Output (P.max) • Connect the positive pressure intake of a differential manometer to the gas valve pressure intake (Pb). • Connect the negative pressure intake of the manometer to a “T” fitting in order to join the boiler compensation intake, the gas valve compensation intake (Pc) and the manometer.
  • Page 29 Gas valve adjustments Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 30 Gas valve adjustments Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 31 Gas valve and connector GAS VALVE SIT GAS VALVE HONEYWELL Connector: Connector: ANSTOSS mod. ANSTOSS mod. VZ2/10 SAC VZ2/10 HDC Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 32 Compactness without loosing in handling  Boiler’s servicing completely from the front side: the careful positioning of all the components allows an easy frontal access and maintenance.  Rapid and precise installation thanks to the 12 cm of distance of the hydraulic connections from the wall.
  • Page 33 Main advantages of a climatic regulation  Central Heating water temperature is adjusted according to the real outdoor temperature;  In case of sudden change of weather, this regulation is able to react quicker than a boiler controlled only by the room thermostat;...
  • Page 34: Connection Of The External Probe

    Connection of the external probe Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 35 Solutions for every demand of heating  The boiler’s PCB can easily be set for the operation of the boiler in traditional heating systems 80/60°C (radiators) or in low temperature systems 45/30°C (under-floor heating systems).  In case of mixed heating systems (high and low temperature), a special controller is available as optional (code KFG714079610).
  • Page 36 Flexibility in the flue installation  Coaxial flue length up to 5 metres, dual flue length up to 30 metres.  Dual flue with AFR system for inlet air regulation to ensure always the maximum combustion efficiency and the lowest emissions. ...
  • Page 37: Dual System

    Dual system KHG 714074810 Accessory to transform the coaxial flue of the boiler in dual flue (length of the pipes up to 30m). Examples of installation (horizontal pipes: two 90° bends and one 45° bend) Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 38 Simple connection to indirect cylinder  Regulation of the cylinder temperature directly on the boiler’s control panel.  Electric three way valve kit to quicken the installation. KHG 714096310 Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 39 Simple connection to indirect cylinder Documento riservato – A solo uso interno / Confidential document – Internal use only...
  • Page 40 The reasons of a 14 kW heating only boiler  The use of more insulating materials in the buildings makes more and more usual the necessity to install boilers that have very low central heating output (6 or 7 kW for a housing of 80-100 m ...