Installation; Ventilate Spray Booth; Configure Gun And Manifold - Graco 26C624 Instructions Manual

Automatic airless spray guns
Table of Contents

Advertisement

Installation

Ventilate Spray Booth

NOTE: Check and follow all National, State, and Local
codes regarding air exhaust velocity requirements.
Check and follow all local safety and fire codes.

Configure Gun and Manifold

(Order manifold separately. See Accessories, page
33.)
Manifolds 241161, 241162, and 26C622
The gun is supplied with an internal fluid plug (4). See
F
. 1. To use the gun in a circulating system, remove
IG
the internal plug. In a non-circulating system, leave the
plug in place to minimize flush time.
Circulating System
1. Apply anti-seize lubricant 222955 to the threads and
mating faces of the manifold (102) and the elbows
(107), supplied unassembled.
2. Install the elbows (107) in both fluid ports of the
manifold (102).
3. Connect the fluid supply line to one elbow and the
fluid return line to the other. The manifold fluid ports
are reversible.
311053L
Non-circulating System:
1. Apply anti-seize lubricant 222955 to the threads and
mating faces of manifold (102), plug (109), and
elbow (107), supplied unassembled.
2. Install an elbow (107) in one fluid port of the
manifold (102), and a plug (109) in the other port.
3. Install the internal plug (4) in the gun fluid port on
the same side as the manifold plug.
4. Connect the fluid supply line to the manifold elbow
(107). See F
. 1.
IG
5. Install the gun on the manifold, using the four
screws (14). Start the threads of all four screws, and
tighten the front two screws first, and then tighten
the back two screws to 65 in-lb (7.3 N•m).
1
Remove when used in circulating systems.
2
Replace with an elbow (107) when used in circulating
systems.
5
6
4
1
109
2
F
. 1: Non-Circulating Setup (Cutaway View)
IG
Installation
102
107
TI8587b
5

Advertisement