Sper scientific 800004 Manual

Sper scientific 800004 Manual

Type k/j thermometers
Hide thumbs Also See for 800004:

Advertisement

Quick Links

Type K/J
Thermometers
800004 & 800007

Advertisement

Table of Contents
loading

Summary of Contents for Sper scientific 800004

  • Page 1 Type K/J Thermometers 800004 & 800007...
  • Page 2: Table Of Contents

    CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . 2 PANEL DESCRIPTION .
  • Page 3: Panel Description

    PANEL DESCRIPTION 1 . Probe Input (top of unit) 2 . Display 3 . °C/°F 4 . Min/Max 5 . Type K/J 6 . REL (relative) / adj 7 . HOLD / Auto Off 8 . Power 9 . T1-T2 (difference 800007 only) 10 .
  • Page 4: Measurement Procedures

    MEASUREMENT PROCEDURES Measurement Mode 1 . Press the POWER button . 2 . Press the °C/°F button to select the temperature scale . “°C” or “°F” will appear on the LCD . 3 . Press the TYPE button to select your sensor type .
  • Page 5 MEASUREMENT PROCEDURES Note… To obtain the most accurate reading, the probe plug must be the same temperature as the socket . Hold Mode 1 . Press the HOLD button during measurement to freeze the displayed temperature . “HOLD” and the temperature are shown .
  • Page 6 MEASUREMENT PROCEDURES 1 . The max value is updated only when exceeded . 2 . With the meter on, press the MAX/MIN button once . “MAX” and the maximum (peak) temperature appear on the LCD . 3 . The min value is updated only when a lower temperature is recorded .
  • Page 7 MEASUREMENT PROCEDURES Relative Measurement 1 . Press the REL button during measurement to store the current temperature into memory . “REL” and “0 .0°” appear on the LCD . 2 . As subsequent temperatures are measured, the difference (higher/lower) appear on the LCD . 3 .
  • Page 8 MEASUREMENT PROCEDURES T1-T2 Δ Mode (800007 Only) Using two probes, model 800007 will display the Δ (difference) between the T1 and T2 temperatures . The MAX/MIN and REL buttons will not operate in Δ Mode. 1 . With the meter on, press the T1-T2 button once .
  • Page 9: Offset Adjustent

    OFFSET ADJUSTMENTS You can adjust the offset to compensate for meter and probe error . 1 . Press and hold REL to enter offset setup mode . 2 . Press TYPE or POWER to increase or decrease the offset value, respectively . The maximum adjustment is ±5°C or ±9°F .
  • Page 10: Auto Power Off

    AUTO POWER OFF 1 . The thermometer will automatically turn off after 15 minutes of inactivity . 2 . Press and hold the HOLD button to disable or enable the auto power off function . BATTERY REPLACEMENT 1 . When the low battery icon is displayed, turn off the meter and remove the probe(s) .
  • Page 11: Specifications

    SPECIFICATIONS Accuracy ±(0 .05% of reading + 0 .7°C or 1 .4°F) when inside the range of 23± 5°C, < 80%RH 0 .01% of reading + 0 .03°C per each °C outside the specified range of 23± 5°C or 73± 9°F Type K -200 ~ 1370°C (-328 ~ 2498°F)
  • Page 12: Optional Accessories

    800060~97 Type K / J Thermocouple Probes 840090 Water Resistant Instrument Pouch 850000 Rubber Boot WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge .

This manual is also suitable for:

800007