Sper scientific 800024 Instruction Manual

4 channel datalogging thermometer
Hide thumbs Also See for 800024:

Advertisement

4 Channel
Datalogging Thermometer
800024
Instruction Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Sper scientific 800024

  • Page 1 4 Channel Datalogging Thermometer 800024 Instruction Manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ..............3 FEATURES ................4 MATERIALS SUPPLIED ............ 4 FRONT PANEL DESCRIPTION ......... 5 LCD DISPLAY ..............6 SET UP ................7 MEASUREMENT PROCEDURES ........12 SOFTWARE INSTALLATION ........... 16 DATALOGGING ..............19 POWER SUPPLY .............. 26 CARE AND MAINTENANCE ..........
  • Page 3: Introduction

    INTRODUCTION This Sper Scientific 4 Channel Datalogging Thermometer (Model 800024) displays data from four thermocouple probes simultaneously on a large backlit LCD. Up to 16,000 data records for each channel can be stored in the meter and saved, graphed and processed on a computer through the included USB interface and software.
  • Page 4: Features

    FEATURES • Four-channel simultaneous display • Customizable High/Low Alarm (Channel 1) • Maximum/minimum/average values • Offset to compensate for probe errors • T1 – T2 Δ delta mode • 16,000 data points stored per channel • Direct upload of data to EXCEL, text, or graph files. •...
  • Page 5: Front Panel Description

    FRONT PANEL DESCRIPTION Thermocouple Input Record Button LCD Display Recall Button Power Button 10. Setup Button Backlight Button 11. Memory Button Maximum/Minimum/ 12. USB Interface/ Average Button Power Supply Data Hold Button 13. Tilt Stand Temperature Unit 14. Battery Compartment Selector...
  • Page 6: Lcd Display

    LCD DISPLAY Low-Battery Icon Minimum Reading Maximum Reading Average Reading Setup Mode Automatic Shutoff Indicator Recording In Process Memory Full Indicator FULL Save Reading In Memory Recall stored reading RECALL Thermocouple type TYPE KJET Temperature reading -8888 Temperature channel T1 T2 T3 T4 Δ...
  • Page 7: Setup

    SETUP Meter On and Off 1. Press POWER to turn the meter on. 2. Press and hold POWER for 3 seconds to turn the meter off. Setup Mode 1. Press POWER to turn the meter on. 2. Press SETUP to enter Setup Mode. 3.
  • Page 8 Time Interval The time interval range for storing data is 1 seconds to 60 minutes 59 seconds. 1. “Int” appears on the display along with the time interval in minutes and seconds. The minutes flash on the display. 2. Press ▲or ▼ to adjust the minutes. 3.
  • Page 9 Alarm High and low alarm values can be set for channel T1. 1. “OFF” or “On” flashes on the display. Press ▲or ▼ to toggle between alarm off and on. 2. With the alarm on, press MEM to set the alarm thresholds. 3.
  • Page 10 T1 - T2 Δ Delta Mode “OFF” or “On” flashes on the display. Press ▲or ▼ to toggle between T1 - T2 Δ Delta Mode off and on. Automatic Shutoff 1. Press ▲or ▼ to disable automatic shutoff or to select 10 or 30 minutes or 1, 2, 4, or 8 hours before automatic shutoff.
  • Page 11 Date and Time 1. The date and time display and the year flashes. Press ▲or ▼ to set the year. 2. Press ► to select the month. Press ◄ if needed to return to a previous selection. 3. Press ▲or ▼ to set the month. 4.
  • Page 12: Measurement Procedures

    MEASUREMENT PROCEDURES 1. Insert the thermocouple(s) into the appropriate port(s). 2. Press POWER to turn the meter on. Backlight 1. Press the backlight button to illuminate the LCD screen. 2. The backlight will shut off automatically after 30 seconds, or press the backlight button to turn it off sooner. Select Temperature Units Press °C °F to toggle between Celsius and Fahrenheit temperature units.
  • Page 13 Data Hold Note… The MIN/MAX/AVG, °C °F, RECALL and SETUP buttons on the meter are disabled during data hold. 1. Press HOLD to freeze the reading on the display. “Hold” appears at the top of the LCD. 2. Press HOLD to return to Normal Mode. Maximum/Minimum/Average Mode Note…...
  • Page 14 Recording Data Note… Most of the buttons on the meter are disabled during recording. All settings must be selected before recording begins. 1. Press REC to begin recording the readings. “REC” displays on the LCD. If 16,000 readings have been stored for a channel, “REC FULL”...
  • Page 15: Memory Function

    Memory Function To save a reading: 1. Press MEM to save the reading on the display. 2. The “MEM 88” symbol lights up for 2 seconds to show the next number of the saved reading, from 00 to 99. To recall a reading: 1.
  • Page 16: Software Installation

    SOFTWARE INSTALLATION System Windows XP / VISTA / 7 / 8 / 10 Requirements Minimum Hardware PC or laptop with CD-ROM Requirements ≥50 MB hard disk space to install SE800024 Screen resolution ≥ 1024 x 768 Note… Different computer systems may require slightly different installation steps than those below.
  • Page 17 4. Once all the initial requirements have been met, make sure that there are no unnecessary programs running before beginning the installation procedure. In some instances, applications may require that the antivirus programs be disabled. Make sure that you are installing a legitimate application before disabling your protection software.
  • Page 18 Uninstalling the Software If you wish to remove SE800024 from your computer, the software may be uninstalled using one of the following methods. Note that your system may require slightly different steps. 1. Click on the Start Menu. 2. Select “Control Panel.” 3.
  • Page 19: Datalogging

    DATALOGGING Recording Real-Time Data in Graph Form 1. Press POWER to turn the meter on. 2. Insert the thermocouple(s) into the appropriate port(s). 3. Connect the meter to the PC using the USB cable provided. 4. Open the SE800024 program. An image of the meter displays along with a real-time graph.
  • Page 20 Tool Bar Options Hide or display the statistics above the graph (Statistic 1.) Hide or display the statistics below the graph (Statistic 2.) Restore normal cursor. Change cursor to an “X.” Click anywhere on the graph to mark it with an “X.” This option is not available when “Split”...
  • Page 21 - Separate the four channel. - Combine the four channel. Viewing the Graph • To zoom in: Press the left mouse button and drag the cursor to select the new area. • To zoom out: Click “Undo Zoom”...
  • Page 22 Customizing the Graph 1. Click “Graph Option” to open the Customization Menu. This allows you to specify the channel displayed, modify the graph style, add a title and subtitle, maximize the graph and export the graph to the clipboard, a file or a printer. - Graph Customization - Change the Y axis extension 2.
  • Page 23 4. Click “Save.” Printing the Graph 1. Click “File” and select “Print,” or simply click the printer icon. 2. Select the destination printer and click “OK.”...
  • Page 24 Downloading Recorded Data Select “Data Logger” from the main menu bar or click (the datalogger icon) under the main menu. An indicator shows the loading progress.
  • Page 25 • The left side of the screen will display the number of data sets with detail information for each set. • The first data set will appear in the graph on the right side. • Click any data set to graph that set.
  • Page 26: Power Supply

    • Do not use abrasives, solvents or cleaning agents containing carbon, alcohol or benzenes on the meter. • Repairs or services not covered in this manual should be performed by qualified personnel only. Please contact Sper Scientific to speak with a technician.
  • Page 27: Specifications

    SPECIFICATIONS Range Resolution Accuracy (excluding probe error) Temperature K -200 to 1372°C 0.1°C < 600°C at ambient temp. of -328 to 2501°F 1°C ≥ 600°C 18 to 28 °C J -200 to 1000°C (64 to 82 °F) -328 to 1832°F 0.1°F <...
  • Page 28: Warranty

    WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) year from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available.

Table of Contents