Sper scientific 800043 Instruction Manual

Sper scientific 800043 Instruction Manual

Ultimate thermometer

Advertisement

Quick Links

ULTIMATE THERMOMETER
800043
Instruction Manual
• IR thermometer
• Pt 100 ohm
• Type K/J/R/E/T

Advertisement

Table of Contents
loading

Summary of Contents for Sper scientific 800043

  • Page 1 ULTIMATE THERMOMETER 800043 Instruction Manual • IR thermometer • Pt 100 ohm • Type K/J/R/E/T...
  • Page 2: Table Of Contents

    CONTENTS I. Panel Description ..................2 II. Introduction ....................3 III. Operating Instructions A. IR Measurement ..................3-4 B. Thermocouple Measurement ..............5 C. Pt 100 OHM Measurement ..............5 D. Data Hold ....................5 E. Data Record ....................5 F. Relative Measurement ................5 G. LCD Back Light ..................6 H.
  • Page 3: Introduction

    II. INTRODUCTION - Combines Infrared, RTD and thermocouple capabilities in a single unit. For general purpose applications chose any type K, J, R, E, or T thermocouple probe. For a precise temperature reading use the PT100 RTD probe. The built-in IR thermometer features a laser guide and adjustable emissivity.
  • Page 4 DISTURBANCE - Objects with low emissivity or objects with a low temperature and high emissivity, emit little infrared energy. For this reason, measurement of these objects is affected by infrared energy radiated from nearby objects with high emissivity or high temperatures. Object When such objects are measured in sunlight for example, radiated energy from the sun is reflected...
  • Page 5: Thermocouple Measurement

    B. THEMOCOUPLE MEASUREMENT (K, J, T, E, R) 1. With the meter on, press the SENSOR button (3) to select your sensor type. The display shows: IR, Pt3850, K, J,T, E, or R. 2. Insert the probe plug into the Thermocouple Input (11). 3.
  • Page 6: Lcd Back Light

    G. LCD BACK LIGHT Press the BACK LIGHT >2SR button (5) for at least 2 seconds. The LCD will light for approximately 10 seconds, then turn off. H. AUTO POWER OFF If no buttons are pushed for approximately 10 minutes, the meter will automatically turn off.
  • Page 7: Specifications

    V. SPECIFICATIONS Type Range Res Accuracy (meter only) PT 100 -200 to 850°C -328 to 1562°F Type K -100 to 1300°C -148 to 2372°F Type J -100 to 1150°C 0.1° ± 0.2% + 0.5°C or 1°F -148 to 2102°F Type T -100 to 400°C -148 to 752°F Type E...
  • Page 8: Optional Accessories

    Input Socket DIN 4 pin socket WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge.