The Steam Extractor (Not Present In Xf331M); The Fan Relay (Only For Xf332M); The Energy Saving Function - Emerson Dixell XF330M Installing And Operating Instructions

Controllers for electric ovens
Table of Contents

Advertisement

2.
With single cycle (ccy=sin) the time display shows
the duration of the steam injection. Use the UP and
DOWN keys to set the value (0÷60s).
3.
With repetitive cycle (ccy=riP) the TIME display
shows 4 for digits. The 2 digits on the right indicate
the injection time, the 2 digits on the left indicate the
time during which the output is off.
Use the UP and DOWN keys to set the value. The
OFF time is automatically calculated according to
the following formula: 60 – ON TIME.
ES. The 4020 number means that the instrument
do a injection cycle of 20s and then stays off for
40s.
4.
To exit: push again the key
timeout to expire.
NOTE1: The steam injection can be stopped pushing
again the INJECTION key
NOTE2: Setting the HSi parameter to 0, the steam is
injected continuously as long as key is pushed.
NOTE3: If ccY= riP (repetitive cycle) and the inhibition
time (TcY) added to the injections time (tco) is grater than
60s, the instrument does cycles with the following period
T= tcY + tco, instead of 60s cycles.
It means that he steam is injected for tco seconds and is
disabled for tcY seconds.
9. The steam extractor (Not present in
XF331M)
The steam extractor can be activated by keyboard or
automatically before the end of a cooking cycle.
9.1 How to activate the extractor by means of
the keyboard
By pushing the EXTRACTOR key
extractor is switched. The status of the extractor is
monitored by the led: if the led is ON the extractor is
working, if the LED is off the extractor is off.
9.2 Automatic activation of the steam extractor
before the end of a cooking cycle
The extractor can be activated automatically some
minutes before the end of a cooking cycle.
1592012000 XF330M XF331M XF332M GB REL1.0 31.08.2015
or wait the
.
the relay of the
To set the time, act as follow:
1.
Push the EXTRACTOR key
display will show the activation time in the following
format: h:mm.
2.
Use the UP and DOWN keys to set the value.
(0÷1h30m).
5.
To exit: push again EXTRACTOR key
wait the timeout to expire.
NOTE: By setting the time to 0, only the manual activation
is enabled.

10. The fan relay (Only for XF332M)

The XF332M is provide with a relay for the fan (terminals
17-18).
The relay is activated when the controller is switched on.
During the steam injection the relay is switched off.
After the steam injection it stays off according to the
setting of the tFS parameters (0÷90m)

11. The Energy Saving function

The Energy Saving function is enabled by pushing the
key. It avoids Ceiling and Bottom outputs from
working together. The 2 outputs are switched on
alternatively.
The tcE and dcy parameters control this function:
1.
The tcE par. (1÷999s) set the Energy Saving cycle
time.
2.
The dcy (0÷100) set the switching on percentage
of the Ceiling output during the Energy Saving
cycle.
ES. With Energy Saving function enabled, tcE=100s and
dcy=60, when there is a contemporary request of
switching on of the ceiling and bottom outputs, the 2
outputs work as explained in the following graph:
Cielo
Platea
If only a output is requested to be switched on, it is
switched on for all the time is necessary.
XF330M XF331M XF332M
till the time
or
Tempo
Tempo
7/12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dixell xf331mDixell xf332m