Start-Up Instructions - Flagro FVO-750 Series Operating Instructions Manual

Indirect fired space heaters
Table of Contents

Advertisement

1.
Position heater properly & on a level surface before operating
2.
Connect Fuel supply to heater
3.
Ensure the (Thermostat / Manual) selector switch is in the "OFF"
position
4.
Attach power supply, 208-230V/1-phase or 208-230V/3-phase to
appropriate receptacle.
5.
Turn disconnect switch (Single or Three phase) depending on power
supply to "ON" position.
6.
Move switch to "MANUAL" position for manual control.
7.
Move switch to "THERMOSTAT" position for thermostatic control.
Please Note:
1. If using Thermostat kit, the heater must be started in Thermostat position.
2 When changing between manual and thermostat operation, the heater
must be left in the "OFF" position until blower fan completely shuts down
before changing position to prevent the burner from locking out.
3. When using a generator for electrical supply, make sure the generator
is properly grounded and is at a 60Hz frequency.
4. In the event that a Generator is being used and runs out of fuel, make sure
the heater switch is in the "OFF" position before restarting generator, failure
to do so may damage heater.
START UP INSTRUCTIONS:
- 8 -
"OR"