Electromagnetic compatibility (EMC) environment
This equipment is for use in home healthcare fa-
cility environment.
This equipment is not likely to cause any harm-
ful interference in nearby equipment; however, it
can be impaired by electromagnetic (EM) inter-
ference emitted by other equipment, which can
lead to malfunctions. Do not use this equipment
where there is a risk that other electrical and/
or electronic equipment can interfere with this
equipment.
This equipment complies with the following
standards
IEC 60601-1-2:2014 Medical electrical equip-
ment - Part 1-2: General requirements for basic
safety and essential performance - Collateral
Standard: Electromagnetic disturbances - Re-
quirements and tests (EN 60601-1-2:2015)
EN 12182:2012, Clause 7, Assistive products for
persons with disability – General requirements
and test methods
E
Testing for EM disturbances (EM emission and EM immunity)
N
Test modes during emission tests:
1.
Movement mode (battery). Actuator running in/out
2.
Charging mode, actuator not running.
EM emission standards
Conducted and radiated RF emission CISPR 11
Harmonic distortion
IEC 61000-3-2
Voltage fluctuations and flicker
IEC 61000-3-3
EMC - WARNINGS
Use of this equipment adjacent to or stacked
with other equipment should be avoided be-
cause it could result in improper operation. If
such use is necessary, this equipment and the
other equipment should be observed to verify
that they are operating normally.
Use of accessories, transducers and cables
other than those specified or provided by R82
could result in increased EM emission or de-
creased EM immunity of this equipment and re-
sult in improper operation. Several power plugs
are supplied with this equipment. Please use
the correct power plug suitable for your country.
Please chose among the supplied power plug
adaptor units: English, Australian, EU, US/Japa-
nese plugs.
Portable radio frequency (RF) communication
equipment (including peripherals such as an-
tenna cables and external antennas) should be
used no closer than 30 cm (12 inches) to any
part of the product, including cables specified by
R82. Otherwise, degradation of the performance
of this equipment could result.
Classification/levels
Group 1 (the product uses RF energy only for its internal
function)
Class B (the product is suitable for use in all establish-
ments, including domestic establishments and those
directly connected to the public low-voltage power supply
network that supplies buildings used for domestic pur-
poses)
Class A.
No testing performed, as the rated power for this equip-
ment is less than 75 W. No limits are specified for equip-
ment with a rated power of 75 W or less.
dmax ≤ 4 % (without additional conditions)