Fuel
CAUTION!
Open the vehicle's fuel tank cap, ventilate the tank and then re-close the tank lock.
Catch any fuel running off with an appropriate container.
Install fuel line and metering-pump wiring harness so that they are protected against stone impact. Un-
less specified otherwise, always fasten using cable ties.
Mount the fuel line and wiring harness with rub protection on sharp edges.
WARNING!
The fuel line and wiring harness are routed to the metering pump in as shown in the wiring harness
routing diagram.
1
2
1
340
265
1314128B_EN
Route fuel line 2in corrugated tube 3 to fire-
3
wall and route to vehicle underbody together
with wiring harness of metering pump.
1 10 mm dia. clamp
2 Fuel line
3 10 mm dia. corrugated tube
31
1 Fuel-tank vent line
80
32
Shorten fuel standpipe 1 to 340 mm length
1
when stretched out and mould.
220
33
Suzuki Splash
Connect-
ing heater
Discon-
necting
fuel-tank
vent line
Preparing
fuel stand-
pipe
16