OTHER PRINTER CONTROL
COMMANDS
Set MS6 to 1
Mode
ASCII
Decimal
Hexadecimal
Both
<ESC>
" > "
27
62
1B 3E
Sets
the most significant bit of each subsequent byte received to 1, allowing
users with a 7-bit interface to access characters with ASCII codes greater
than 127.
-
Set MSB to 0
Mode
ASCII
Decimal
Hexadecimal
1
Std.
<ESC>
"="
27
61
1B 3D
-.
IBM
<FS>
"c"
28
61
1C 3D
Sets the most significant bit of each subsequent
byte received to 0.
-
Accept MSB as is
Mode
ASCII
Decimal
Hexadecimal
Both
<ESC>
"#"
21
35
1B
23
Cancels the preceding commands and accepts the most significant bit as
it is sent to the printer.
Delete last character
sent
Mode
ASCII
Decimal
Hexadecimal
Both
<DEL>
127
IF
Deletes the last character received. Ignored if the last character received
has already been printed, or if the last character received was all or part
of a command.
Cancel last line
Mode
ASCII
Decimal
Hexadecimal
Both
<CAN>
24
18
Deletes the last line currently present in the print buffer.