Cancels all current horizontal
tab stops and sets new tab stops every n
columns, where n is between 1 and 127.
Reset a// tab stops
Mode
ASCII
Decimal
Hexadecimal
IBM
<ESC>
"R"
21 82
1B
52
Resets the horizontal
tab stops to their power-up values in which a tab
stop is set every 8 column starting at column 9. Also clears all vertical
tab stops.
Horizontal tab
Mode
ASCII
Decimal
Hexadecimal
Both
<HT>
9
09
Moves the print position to the next horizontal tab stop. Ignored if there
is no next horizontal
tab stop in the current line. Note that when un-
derlining
is selected, spaces skipped by horizontal
tabulation
are not
underlired.
Relative horizontal tab
Mode
ASCII
Decimal
Hexadecimal
Std.
< ESC >
"\"
nl
n2
21 92 nl
n2
IB
SC
nl
n2
IBM
< FS >
"\"
nl
n2
28 92 nl
n2
IC SC nl
n2
Moves the print position right or left a specified distance (maximum
6
inches). Ignored if the resulting position is beyond the right or left margin.
The formulas for the distance and direction are as follows:
If n2 is between 0 and 63, the print head moves right by (nl + n2 x 256)/120
inches
If n2 is between
64 and 127, the print head moves left by (nl
+
[n2 - 641 x 256)/ 120 inches
Absolute horizontal tab in
inches
Mode
ASCII
Decimal
Hexadecimal
Both
<ESC>
'3"
nl
n2
21 36 nl
n2
IB
24
nl
n2
Sets the next print position to (nl + n2 x 256)/60 inches from the left
margin on the current line. Ignored if this position is beyond the right
margin. The maximum position is 8 inches.