Download Print this page

Electrical Connection; How The Downdraft Works - Caple DD606BK Instruction Manual

Downdraft hood
Hide thumbs Also See for DD606BK:

Advertisement

E L E C T R I C A L C O N N E C T I O N
W A R N I N G
Place the metal box containing the electronic components at a distance of no less than 65cm from
gas operated hobs or in any case, 65cm from the suctioning surface of the cooker hood.
N OT E
We recommend installing the metal box containing the electronic components at least 10cm
above floor level and at a suitable distance from all heat sources (e.g. ovens or hobs).
C A U T I O N
This appliance is fitted with an H05 VVF 3 conductor, 0.75mm2 (neutral, phase, and ground)
power cord.
This can be connected up to a 220 - 240 V monophase electrical network through a CEI 60083
approved power socket, which must remain accessible after installation, in compliance with
installation regulations. We decline any responsibility in case of accidents caused by a lack
of ground connection or incorrect ground connection. The appliance must be fed through a
differential protection device (RCD), with a nominal residual current not exceeding 30mA. If the
power cord is damaged, call the Caple after-sales service to avoid any risk.
W A R N I N G
The downdraft connection to the electrical network must be carried out only by professional and
qualified technicians.
The downdraft must be connected to a properly installed and suitable electrical network.
The electrical system must comply with VDE0100 standard.
DA N G E R
If the cooker hood presents any anomaly, disconnect the appliance or remove the fuse
corresponding to the appliance power disconnecting line. If the appliance has no plug or if the
plug is not easily accessible, then a device needs to be fitted to cut it off from the electric network;
this device must have an opening distance between contacts on all poles of at least 3mm.
E L E C T R I C A L C O N N E C T I O N
While installing the appliance and carrying maintenance operation, make sure it is disconnected
from the electrical network or the fuses are cut out or removed.
12
Instruction manual DD606BK
Please keep this instruction manual for future reference
Check that:
- Power is enough.
- Feeder lines (mains) are in good condition.
- The cable diameter complies with installation regulations.
H O W T H E D O W N D R A F T W O R K S
L O W E R T H E E X T R A C T I O N PA N E L - ' 0 ' S W I T C H
- This serves to close the extraction panel either completely or in intermediate positions above
180mm from the hob. When the extraction panel is being closed, it will remain in operation
until it reaches 180mm above the hob. Below this height, the extraction function will switch off
automatically.
R A I S E T H E E X T R A C T I O N PA N E L , S W I T C H O N - S P E E D 1
- This serves to bring the extraction panel up to a maximum height of 300mm and to automatically
set the first extraction speed when the panel reaches a height of 180mm. Pressing the button
when this height is reached makes it possible to place the extraction panel in the required
intermediate positions, up to a maximum of 300mm, while leaving the extraction speed of the
motor unchanged.
S P E E D 2 S W I T C H
S P E E D 3 S W I T C H
S P E E D 4 S W I T C H
- These serve to set the respective suction speeds after the extraction panel has reached 180mm
above the hob and to set the height of the extraction panel to a maximum of 300mm by pressing
the same button.
T I M E R
- 10 minutes after pressing this button and setting the function, it serves to stop the extractor
motor and close the carriage. The set function is signalled by the flashing LEDs "D" for the set
speed. The timer can be cancelled by press-ing the key again.
Please keep this instruction manual for future reference
Instruction manual DD606BK
13

Advertisement

loading