11. Attaching a Brush Adapter for Chip Cleaning

A commercially available vacuum cleaner is used during cutting to keep chips from flying into the box. Attaching the brush adapter
included with the PNC-300 can enhance chip-cleaning performance.
Before attaching the brush adapter, first clean away any chips that may be present on the mounting surface.

12. Sending Cutting Data

The PNC-300 performs cutting after receiving cutting data from the computer (application software).
Data may be output, for example, after it has been created using any of a number of applications, or from driver software.
In this section, general matters related to data output are explained. Refer to this section when carrying out data output. For details of
the cutting data output method, refer to the operation manual for the application software or driver software used.
Setting the Output device
Please select from among the models shown below when making the settings for output device with the application software.
Output model
PNC-300
CAMM-3 Series
* When set to "AUTO," the machine automatically determines whether the mode 1 or mode 2 instruction system is used.
Sample Settings for Application Software
Select PNC-300. If it is
not listed, select CAMM-
3 series.
Select either the parallel
(Centronics) or the serial
(RS-232C) interface.
Choose the one that the
host computer and the
PNC-300 are connected
by.
Cautions During Cutting
Opening the cover during cutting results in an emergency stop. Any cutting data in use becomes invalid, and cutting cannot be contin-
ued.
If the cover must be opened during cutting, first press the [ENTER/PAUSE] key to pause the unit. Confirm that operation has stopped,
and then open the cover. After the cover has been closed, cutting resumes when the paused state is canceled.
The spindle will not rotate while the cover is open.
Instruction system
CAMM-GL I (mode1, mode2)
CAMM-GL I (mode1, mode2)
Output device selection
Device name
[PNC-300]
PNC-300
PNC-3100
PNC-3000
PNC-2700
Interface
Centronics
[RS-232C]
RS-232C
NOTICE
You should never bring floppy disks close to
brush adapter, since the data on them could be
erased.
Command setting on the
PNC-300
"AUTO"
"AUTO"
Protocol
9600
4800
Baud rate
2400
Data bit
Stop bit
Parity
Handshake
OK
CANCEL
Coordinate unit setting on
the PNC-300
"0.01 mm"
"0.01 mm"