T E C H N I C A L I N F O R M A T I O N
CLV62x, CLV63x and CLV64x with IP69K Protec‐
tive Housing
Bar Code Scanners

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLV63 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK CLV63 Series

  • Page 1 T E C H N I C A L I N F O R M A T I O N CLV62x, CLV63x and CLV64x with IP69K Protec‐ tive Housing Bar Code Scanners...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐...
  • Page 3: Table Of Contents

    Accessories..................34 Brackets....................Cables......................8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing Subject to change without notice...
  • Page 4: About This Document

    … indicates a potentially dangerous situation, which may lead to minor/slight injuries if not prevented. T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 5 … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 6: Safety Information

    (PLC) for coordinating further processing. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 7 "Type label", page 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 8 Irrespective of the selected configuration type, the laser timeout can be set as follows: T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 9 If timeout is activated, it will have no effect here. 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 10: Product Description

    Date of manufacture à T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 11: Design

    Light emission position (central position of the deflected laser beam) Protective double bushing for the electrical connections 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 12 Protective double bushing for the electrical connections T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 13: Scope Of Delivery

    IP69K protective housing 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 14: Differences Between Devices In Ip65 Standard Housing And Devices In Ip69K Protective Housing

    CLV63x and CLV64x: 2 T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 15: Reading Fields

    The following table shows the reading fields of two comparable bar code scanners with front reading window by way of example. 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 16 T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 17 As a simplified rule: the depth of field is reduced by approx. 10% for devices with a plas‐ tic reading window. 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 18: Transport And Storage

    T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 19: Mounting

    Mount the device on an optional SICK bracket. The device is mounted on the ■ bracket by means of the 2 M5 threaded holes. For the optional SICK brackets, see www.sick.com. Mount the device on a user-supplied bracket. You can mount the device on the ■...
  • Page 20: Mounting The Protective Double Bushing On The Protective Housing

    Protective double bushing T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 21 12. Position O-rings in the provided grooves of the protective double bushing. 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 22: Assembly Without Use Of The Ethernet Connection

    Dummy plug for “Ethernet” feedthrough T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 23 Figure 19: Assembly of IP69K protective housing, without use of the Ethernet connection 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 24: Electrical Installation

    "Cables", page 34 ■ T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 25: Prerequisites For Safe Operation Of The Device In A System

    Digital switching input (external reading cycle) – – 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing Subject to change without notice...
  • Page 26 Function – – T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/0000/2018-03-12 | SICK Subject to change without notice...
  • Page 27: Technical Data

    Data transmission rate: 10/100 Mbit/s, half/full duplex Protocol: TCP/IP, EtherNet/IP, PROFINET Single Port 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 28 TECHNICAL DATA CLV620 Function: SICK CAN sensor network (master/slave, multiplexer/server) Data transmission rate: 20 kbit/s ... 1 Mbit/s Protocol: CSN (SICK CAN sensor network), CANopen PROFINET PROFINET Dual Port optional over external fieldbus module CDF600-2 EtherCAT ® Optional via external fieldbus module CDF600...
  • Page 29: Bar Code Scanner Clv63X In Ip69K Protective Housing

    1 ... 50 (auto-discriminating) interval 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing Subject to change without notice...
  • Page 30 Ethernet Function: Host, AUX Data transmission rate: 10/100 Mbit/s, half/full duplex Protocol: TCP/IP, EtherNet/IP, PROFINET Single Port Function: SICK CAN sensor network (master/slave, multiplexer/server) Data transmission rate: 20 kbit/s ... 1 Mbit/s Protocol: CSN (SICK CAN sensor network), CANopen PROFINET...
  • Page 31: Bar Code Scanner Clv64X In Ip69K Protective Housing

    MTTF (laser diode) 40,000 h at 25 °C 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 32 Ethernet Function: Host, AUX Data transmission rate: 10/100 Mbit/s, half/full duplex Protocol: TCP/IP, EtherNet/IP, PROFINET Single Port Function: SICK CAN sensor network (master/slave, multiplexer/server) Data transmission rate: 20 kbit/s ... 1 Mbit/s Protocol: CSN (SICK CAN sensor network), CANopen PROFINET...
  • Page 33 2,000 lx, on bar code Bar code print contrast (PCS) ≥ 60% 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing...
  • Page 34: Accessories

    ACCESSORIES Accessories Brackets SICK offers prefabricated brackets which are optimally suited for mounting the device in a wide range of applications. Also see on Internet at: www.sick.com/CLV62x ■ www.sick.com/CLV63x ■ www.sick.com/CLV64x ■ Figure 22: Example of optional bracket for bar code scanners CLV62x, CLV63x and CLV64x with...
  • Page 35 6050596 As 6050198, but length 20 m 8021479/0000/2018-03-12 | SICK T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing Subject to change without notice...
  • Page 36 Phone +36 1 371 2680 Phone +386 591 788 49 E-Mail office@sick.hu E-Mail office@sick.si India South Africa Phone +91 22 6119 8900 Phone +27 11 472 3733 Further locations at www.sick.com E-Mail info@sick-india.com E-Mail info@sickautomation.co.za SICK AG | Waldkirch | Germany | www.sick.com...