Page 1
O P E R A T I N G I N S T R U C T I O N S CLV69x Bar code scanners...
Page 2
Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Pin allocation of the connections............Connection diagrams................Wiring interfaces..................Connection modules................8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 4
14.4 Dimensional drawings................127 14.5 Abbreviations used................... 127 14.6 Glossary..................... 128 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
… indicates a potentially dangerous situation, which may lead to a fatality or serious injuries if not prevented. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Before calling, make a note of all type label data such as type code, serial number, etc., to ensure faster processing. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
The manufacturer accepts no liability for damage caused by: 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Knowledge of the operation and control of the devices in ■ their particular application O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Figure 1: Laser output aperture in the different designs 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 10
Irrespective of the selected configuration type, the laser timeout can be set as follows: O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
SICK AG. Interruptions or modifications to the device by the customer will inva‐ lidate any warranty claims against SICK AG. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Refers to the longitudinal axis of the device. For available interfaces, see respective cloning plug (accessories) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Vertical to the device longitudinal axis for oscillating mirror â 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 14
Interfaces to external O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 15
8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 16
CLV6xx, parameters, read configuration, focus control, options tab, auto focus parameters O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 17
One-Shot: single deflection (approach and return) per read cycle from an adjusta‐ ble start position 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 18
O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 19
The reading process can alternatively be started with a command string via the data interface. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
For storage periods of longer than 3 months, check the general condition of all ■ components and packaging on a regular basis. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Only in variants with integrated heating (included in the basic scope of delivery) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Figure 11: Example of mounting a CLV69x with a quick clamping device and a mounting bracket O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Figure 13: Line scanner (top view) and line scanner with oscillating mirror (side view) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 24
Figure 14: Line scanner: Read angle occurring between scanning line and bar code Depth of field Reading distance O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 25
8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
"Adjust the device", page Mounting with shock mounts (optional) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 27
8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 28
Mounting of line scanner (horizontal reading line), mounting bracket with inte‐ grated vibration/shock attenuation O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 29
Mounting of line scanner (vertical reading line), ball joint bracket and mounting bracket with integrated vibration/shock attenuation 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
If the device is triggered via an external read cycle sensor (photoelectric retro-reflective sensor), then the sensor must be mounted in the vicinity of the device. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 31
Create direct and secure contact with the drive technology and ensure that friction wheel turns without slipping. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Amended supply voltage range: DC 21.6 V ... 28.8 V ■ O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Figure 20: Occurrence of equipotential bonding currents in the system configuration 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 34
For smaller installations with only slight potential differences, insulated mounting of the device and of peripheral devices may be a sufficient solution. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
D-Sub-HD male connector. The IP65 enclosure rating is only achieved with screwed plug connectors or cover caps. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Signals are not available on the 15-pin D-Sub HD male connector of all adapter cables For external fan O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 37
Figure 23: Cloning plug A, D-Sub HD: Power/Serial Data/I/O/ CAN 1/2 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 38
All lengths in mm Figure 25: Cloning plug A, D-Sub HD: Power/Serial Data/I/O/ CAN 1/2 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 39
Figure 27: Cloning plug B, M12: Power/Serial Data/I/O/Ethernet/CAN 1 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 40
All lengths in mm Figure 29: Cloning plug C, M12: Power/Serial AUX/IO/CAN 1 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 41
Figure 31: Cloning plug D, M12: Power/Serial AUX/IO/CAN 1/2 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 42
All lengths in mm Figure 33: Cloning plug E, M12: Power/Ethernet/CAN 1 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 43
Figure 35: Cloning plug F, M12: Power/CAN 1/Ethernet/CAN 2 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
*) For the additional use of the external switching inputs and outputs, the optional CMC600 parameter memory module is required. Figure 37: Connection of the device to the CDM420-0006 connection module O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
(e.g. fan, PC using serial interface). 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 46
Max. 500 m For RS-422/485-suitable cable and corresponding cable termination as per specification O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 47
Power at the input starts the internal reading interval of the device (default: active high, debounce: max. 30 ms (standard)) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 48
If the wiring of the inputs is carried out via a connection module, then the relevant oper‐ ating instructions for the module must be followed. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 49
The maximum capacity of 100 nF is a limit value. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
= For the additional use of the external switching inputs and outputs, the optional CMC600 parameter memory module is required. Figure 43: Wiring overview (1 switching input used) for CLV69x-xxx0 (without heating) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 51
Figure 44: Wiring overview (1 switching input used) for CLV69x-xxx1 (with heating) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 52
Recommended setting for all connection work. Figure 45: Wire supply voltage for CLV69x-xxx0 (without heating) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 53
Figure 46: Wire supply voltage for CLV69x-xxx1 (with heating) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 54
6053232 (5 m) Figure 47: Wire serial host interface RS-232 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 55
“RS-422 operation”), i.e. not RS-485 bus operation. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 56
This wiring is not permitted in the standard data output/protocol for the device. In case of doubt, contact SICK Service. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 57
6053232 (5 m) Figure 50: Wiring the CAN interface 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 58
≤ 5 mA Figure 51: Wiring switching inputs “Sensor 1 and 2” O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 59
Figure 52: Wiring switching inputs “External input 1 and 2” 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 60
Figure 53: Wiring switching outputs “Result 1 to 4” O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 61
Figure 54: Wiring switching outputs “External output 1 and 2” 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 62
= For additional use of external switching inputs and outputs, the optional CMC600 parameter memory module is required. Figure 55: Wiring overview (1 switching input used) for CLV69x-xxx0 (without heating) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 63
Figure 56: Wiring overview (1 switching input used) for CLV69x-xxx1 (with heating) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 64
Recommended position for all connection types. Figure 57: Wire supply voltage for CLV69x-xxx0 (without heating) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 65
Figure 58: Wire supply voltage for CLV69x-xxx1 (with heating) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 66
No. 2061481 (5 m) Figure 59: Wire serial host interface RS-232 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 67
“RS-422 operation”), i.e. not RS-485 bus operation. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 68
This wiring is not permitted in the standard data output/protocol for the device. In case of doubt, contact SICK Service. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 69
(max. 32 participants) Figure 62: Wiring the CAN interface 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 70
≤ 5 mA Figure 63: Wiring switching inputs “Sensor 1 and 2” O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 71
Figure 64: Wiring switching inputs “External input 1 and 2” 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 72
SOPAS-ET configuration software! Figure 65: Wiring switching outputs “Result 1 and 2” O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 73
Figure 66: Wiring switching outputs “External output 1 and 2” 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 74
Figure 67: Wiring overview, part 1 (basic map below left), for CLV69x-xxx0 (without heating) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 75
Figure 68: Wiring overview, part 1 (basic map below left), for CLV69x-xxx1 (with heating) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 76
Figure 69: Wiring overview, part 2 (I/O map top right), 1 switching input used O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 77
Figure 70: Wire supply voltage for CLV69x-xxx0 (without heating) 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 78
Figure 72: Wire serial host interface RS-422 O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 79
This wiring is not permitted in the standard data output/protocol for the device. In case of doubt, contact SICK Service. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 80
(max. 32 participants) Figure 74: Wiring the CAN interface O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 81
Figure 75: Wiring switching inputs “Sensor 1 to 6” 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 82
≤ 100 mA Figure 76: Wiring switching outputs “Result 1 to 4” O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Path: Start > Programs > SICK > SOPAS ET Engineering Tool > SOPAS. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Parameter set in the working memory of the device Factory-set defaults for the device O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
CAN bus. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 86
Use the “Ethernet” page to make adaptations to the IP address and the subnet mask (Device tree > Parameters > Network/Interfaces/IOs > Ethernet). O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 87
Test and, if necessary, modify the specified settings when operating the system under real conditions. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
“Ready” LED now lights up blue. Press arrow key repeatedly to select the desired function (LED lights up blue). O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
The SOPAS ET configuration software is used for device diagnostics in case of a fault. In normal operation, the device operates fully automatically. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
The type of screen material used in the reading window can be found on the type label, see "Type code", page O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 91
Contamination on these sensors can result in faulty switching behavior. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 92
Figure 81: Cleaning the external optical sensors (read pulse encoder) O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
The device distinguishes between four types of fault: Information ■ Warning ■ 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Before calling, make a note of all type label data such as type designation, serial num‐ ber, etc. to ensure faster telephone processing. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Description of the application ■ Description of the fault that occurred ■ 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
No. of codes per read‐ 1 ... 50 (auto-discriminating) ing interval O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Electrical connection 60-pin system connection for connecting a cloning plug 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
±45° Ambient light <2000 lx Good read rate >75% O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 99
Scanning frequency characteristic curve page 124 Deflection width page 124 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 100
Figure 82: CLV690-0xxx (Standard Density): reading field height depending on the reading distance and resolution O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 101
Figure 83: CLV690-0xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle a = 40° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 102
Figure 84: CLV690-0xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle a = 56° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 103
Figure 85: CLV690-0xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.50 mm and aperture angle a = 40° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 104
Figure 86: CLV690-0xxx (Standard Density): min. and max. radial reading distance depending on focus position and resolution 0.50 mm and aperture angle a = 56° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 105
Figure 88: CLV690-1xxx (Standard Density): reading field height depending on the reading distance and resolution 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 106
Figure 89: CLV690-1xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle α = 40° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 107
Figure 90: CLV690-1xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle α = 50° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 108
Figure 91: CLV690-1xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.50 mm and aperture angle α = 40° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 109
Figure 92: CLV690-1xxx (Standard Density): min. and max. radial reading distance depending on focus position with resolution 0.50 mm and aperture angle α = 50° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 110
Figure 94: CLV690-1xxx (Standard Density): deflection width depending on the radial reading distance, angle of deflection and resolution O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 111
Figure 95: CLV691-0xxx (Low Density): reading field height depending on the reading distance and tilt with resolution 0.5 mm 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 112
Figure 96: CLV691-0xxx (Low Density): min. and max. radial reading distance depending on focus position with resolution 0.5 mm and aperture angle α = 40° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 113
Figure 97: CLV691-0xxx (Low Density): min. and max. radial reading distance depending on focus position with resolution 0.5 mm and aperture angle α = 60° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 114
Figure 99: CLV691-1xxx (Low Density): reading field height depending on the reading distance and tilt with resolution 0.5 mm O P E R A T I N G I N S T R U C T I O N S | CLV69x...
Page 115
Figure 101: CLV691-1xxx (Low Density): deflection width depending on the radial reading distance, angle of deflection and tilt with resolution 0.5 mm 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 116
Figure 102: CLV692-0xxx (High Density): reading field height depending on the reading distance and resolution O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 117
Figure 103: CLV692-0xxx (High Density): min. and max. radial reading distance depending on focus position with resolution 0.25 mm and aperture angle α = 40° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 118
Figure 104: CLV692-0xxx (High Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle α = 40° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 119
Figure 105: CLV692-0xxx (High Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle α = 56° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 120
Figure 107: CLV692-1xxx (High Density): reading field height depending on the reading distance and resolution O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 121
Figure 108: CLV692-1xxx (High Density): min. and max. radial reading distance depending on focus position with resolution 0.25 mm and aperture angle α = 40° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 122
Figure 109: CLV692-1xxx (High Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle α = 40° O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 123
Figure 110: CLV692-1xxx (High Density): min. and max. radial reading distance depending on focus position with resolution 0.35 mm and aperture angle α = 50° 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 124
Figure 112: CLV692-1xxx (High Density): deflection width depending on the radial reading distance, angle of deflection and resolution O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Accessories and where applicable mounting information can be found online at: www.sick.com/CLV69x 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Number of bars = (number - 8)/4 Calculated code length Code O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Rich Text Format (standardized document format with format description) Secure Digital 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Code geometry Length and height dimensions of the code. O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK Subject to change without notice...
Page 129
Ethernet interface can be used alternatively and also in parallel to the physical RS-232, RS-422/485 interfaces. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 130
CAN SENSOR network as a gateway. Provides different transfer protocols (apart from for CAN). O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 131
RA value on an application-specific basis. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 132
(configuration, display of reading results, diagnosis) and the prepared offline configuration of stand-alone devices or the O P E R A T I N G I N S T R U C T I O N S | CLV69x 8014396/ZMG8/2017-07-04 | SICK...
Page 133
The parameter values must be displayed in the tabs in order to be able to modify the current parameter value set. 8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x Subject to change without notice...
Page 134