Barcode Scanner CLV62x
CLV62x
Bar Code Scanner
Standard Line
Online Help
O N L I N E H E L P

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLV62x and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK CLV62x

  • Page 1 Online Help O N L I N E H E L P Barcode Scanner CLV62x CLV62x Bar Code Scanner Standard Line...
  • Page 2: Software Versions

    Internet Explorer are registered trademarks or trade- marks of the Microsoft Corporation in the USA and other countries. Acrobat Reader is a trademark of Adobe Systems Incorporated. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 3: Table Of Contents

    2.2.5.4 Digital inputs ..................35 2.2.5.5 RDT400....................36 2.2.5.6 Digital outputs ..................36 2.2.5.7 Fieldbus CDF600 ...................38 Service ......................38 2.3.1 Operating data ....................38 2.3.2 System status .....................39 Analysis ......................39 2.4.1 Event monitor....................39 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 4 Contents Online Help Barcode Scanner CLV62x © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 5: Notes On This Document

    This symbol refers to special features. Note This symbol refers to additional settings in the configuration software SOPAS-ET. Important This symbol refers to additional technical documents. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 6 Notes on this document Chapter 1 Online Help Barcode Scanner CLV62x © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 7: Clv62X

    You can activate/deactivate this function here. Important Default values, min. and max. values are displayed at P on the SOPAS-ET in- ARAMETER INFO terface. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 8: Parameter

    Codelabel properties group can be gouped into up to eight configurations. The organization of the configurations is done on page chapter 2.2.1.3 Dynamic reading configuration, page © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 9: Object Trigger Control

    If applicable, select unit. Start Sensor 1 50 ms 100 ms Reading gate Fig. 2-1: Impact of the parameters Start delay and Stop delay on the reading gate. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 10: Illumination Control

    Dyn. reading config. assignment table group. Parameter Function Assignment table length Enter the number of configurations that are assigned. Index 0..7 Set the order for assigning the configurations. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 11: Increment Configuration

    Fixed speed Enter speed of the conveyor distance. If applicable, select unit. System increment resolution Enter resolution of the external incremental encoder. If applicable, select unit. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 12: Code Configuration

    With this code type the reading distance must be entered (see chapter 2.2.1 Reading configuration, page All the other code types are locked via activation of the code type HARMACODE © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 13: Codabar

    Only barcodes with lengths between these two values are read. Fixed lengths Enter required lengths of the barcode. Only barcodes with the entered lengths are read. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 14: Code 39

    Enter maximum length of barcode. Only barcodes with lengths between these two values are read. Fixed lengths Enter required lengths of barcode. Only barcodes with the entered lengths are read. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 15: Upc/Ean

    Activate/deactivate scanning of code type UPC E UPC E Activate/deactivate scanning of code type UPC E Extended UPC E E Activate/deactivate scanning of code type XTENDED 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 16: 2/5 Interleaved

    Enter maximum length of barcode. Only barcodes with lengths between these two values are read. Fixed lengths Enter required lengths of barcode. Only barcodes with the entered lengths are read. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 17: Code 93

    Enter maximum length of barcode. Only barcodes with lengths between these two values are read. Fixed lengths Enter required lengths of barcode. Only barcodes with the entered lengths are read. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 18: Code 128 Family

    Enter maximum length of barcode. Only barcodes with lengths between these two values are read. Fixed lengths Enter required lengths of barcode. Only barcodes with the entered lengths are read. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 19: Pharmacode

    Parameters Function Length Enter required length of barcode. For safety reasons, only pharmacodes with at least four digits can be read. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 20: Data Processing

    Separate codes based on posi- Activate/deactivate the output of similar codes as several codes. tion Code distance Enter maximum distance of codes from each other. If applicable, select unit. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 21: Output Control

    Reading gate 100 ms Output time Fig. 2-11: Impact of the parameter values End of trigger (Output time) on the output time of the code contents. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 22 Code 100 ms Output time Fig. 2-13: Impact of the parameter values End of label (Output time) on the output time of the code contents. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 23: Evaluation Conditions

    Close window and confirm entries. This button is greyed out as long as all the codes match the condi- tion. Cancel Close window and reject entries. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 24 Limitation on devices with ID Enter the device IDs of the devices for which this condition should be applied. Invert condition Activate/deactivate inversion of the condition. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 25 If the condition is true, the result is false. Add bracket around part conditions. Add bracket around part conditions. Remove row Remove part condition or link between two conditions. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 26 No valid code could be read: output of "NoRead" in the output string. In order to achieve such a result the following and an appropriate CONDITION OUTPUT FORMAT must be created (see chapter 2.2.4.5 Output format, page 29). © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 27: Match-Code Teach-In 1

    Select trigger source for teach-in of evaluation condition. Teach-in code content Activate/deactivate teach-in of code content. Teach-in code ID (type) Activate/deactivate teach-in of code ID. Teach-in code length Activate/deactivate teach-in of code length. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 28: Filter/Sorter For Output Formatting

    To copy a filter/sorter by drag & drop, press the Ctrl button. To delete a filter/sort- er, drag it into the recycle bin (mouse pointer must be above recycle bin). © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 29: Output Format

    The created output format can be marked and copied into a text editor for saving. To copy it back, right-click on the Output format #1 window and select "P ...". ASTE FROM EXTERN 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 30 The created output format can be marked and copied into a text editor for saving. To copy it back, right-click on the Heartbeat format window and select "P ...". ASTE FROM EXTERN © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 31: Network / Interface / Ios

    Enter device name. This name is displayed at the top of the project tree. Master / Slave The master / slave connection of the scanner in the SICK CAN sensor network is defined via the parameters of the Master / Slave group.
  • Page 32: Serial

    Enter time between two heartbeats. Restart interval on sending Restart interval after the output of a reading result. Gateway Activate PROFIBUS DP interface or DeviceNet respectively. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 33: Ethernet

    Enter IP address of scanner. Subnet mask Enter subnet mask of scanner. Default gateway Enter default gateway of scanner. Speed Select network speed. MAC address Enter MAC address of scanner. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 34 Enter the address of the RDT400 server to which the bar code scanner sends the data. The webserver function of a scanner is activated/deactivated via the parameters of the EBSERVER Webserver group. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 35: Can

    Select sensitivity of sensor. Logic Select logic of the external input 1. Debouncing Enter detection time for signal at the external input 1. If applicable, select unit. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 36: Rdt400

    Select event that is to trigger a signal at output 1. Logic Select logic level of the selected output 1. Control Select type of control. Duration Enter signal duration. If applicable, select unit. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 37 The beeper is configured with the parameters of the Beeper group. Parameter Function Beeper Select condition which is to trigger the beeper. Volume Select the beeper volume. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 38: Fieldbus Cdf600

    The date of the last parameterisation is indicated. The time of the last parameterisation is indicated. Last maintenance Enter date of the last maintenance Next maintenance Enter date of the next maintenance. © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...
  • Page 39: System Status

    Set zoom of the diagram to 100 %. Scale down diagram. Indicate time axis in diagram. Indicate increment axis in diagram. Activate/deactivate matrix in diagram. Indicate values in diagram. 8011967/S345/2008-04-23 © SICK AG · Division Auto Ident · Germany · All rights reserved...
  • Page 40 Deutschland Singapore España Suomi France Sverige Great Britain Taiwan India Türkiye Italia USA/Canada/México Japan Nederlands Norge Österreich www.sick.com SICK AG | Waldkirch | Germany | www.sick.com © SICK AG · Division Auto Ident · Germany · All rights reserved 8011967/S345/2008-04-23...