Allen-Bradley A Series Installation Instructions Manual
Allen-Bradley A Series Installation Instructions Manual

Allen-Bradley A Series Installation Instructions Manual

Devicenet network powered 16-input module
Hide thumbs Also See for A Series:

Advertisement

Quick Links

Installation Instructions
DeviceNet ArmorBlockā„¢ Network
Powered 16-input Module
Catalog number 1732D-IBDPM12MND, Series A

Table of Contents

Topic
Page
2
3
3
4
5
5
5
6
8
9
10
12

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley A Series

  • Page 1: Table Of Contents

    Installation Instructions DeviceNet ArmorBlock™ Network Powered 16-input Module Catalog number 1732D-IBDPM12MND, Series A Table of Contents Topic Page Important User Information Environment and Enclosure Preventing Electrostatic Discharge About the Module Catalog Number Explanation Install the Module Set the Node Address Mount the Module Connect the Cordsets Communicate with the Module...
  • Page 2: Important User Information

    2 DeviceNet ArmorBlock™ Network Powered 16-input Module Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices.
  • Page 3: Environment And Enclosure

    DeviceNet ArmorBlock™ Network Powered 16-input Module Environment and Enclosure ATTENTION: This equipment is intended for use in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11.
  • Page 4: About The Module

    4 DeviceNet ArmorBlock™ Network Powered 16-input Module About the Module The DeviceNet 1732D ArmorBlock I/O family consists of standalone 24V DC I/O modules that communicate via the DeviceNet network. The sealed IP67 housing of these modules requires no enclosure. Note that environmental requirements other than IP67 may require an additional appropriate enclosure.
  • Page 5: Catalog Number Explanation

    DeviceNet ArmorBlock™ Network Powered 16-input Module The DeviceNet network uses advanced network technology, producer/consumer communication, to increase network functionality and throughput. Visit our web site at www.ab.com/networks for producer/consumer technology information and updates. Catalog Number Explanation The catalog number 1732D-IBDPM12MND refers to a DeviceNet 24V DC 8-port, 16-input mini-style network connector module.
  • Page 6: Mount The Module

    6 DeviceNet ArmorBlock™ Network Powered 16-input Module Node Address Default Setting This example shows the default node address set at 63. 43968 The rotary switches are read periodically. If the switches have been changed since the last time they were read and no longer match the online address, a minor fault occurs, which is indicated by the module indicator flashing red.
  • Page 7 DeviceNet ArmorBlock™ Network Powered 16-input Module Module Dimensions 65 (2.56) 43.25 (1.70) Millimeters 26.5 (inches) (1.04) I - 0 I - 15 I - 1 I - 14 179 (7.05) I - 2 I - 13 I - 3 I - 12 I - 4 I - 11 169 (6.64)
  • Page 8: Connect The Cordsets

    8 DeviceNet ArmorBlock™ Network Powered 16-input Module Connect the Cordsets The ArmorBlock DeviceNet family has 5-pin micro-style connectors. We provide caps to cover the unused connectors on your module. Connect the quick-disconnect cordsets you selected for your module to the appropriate ports. ATTENTION: To comply with the CE Low Voltage Directive (LVD), all connected I/O must be powered from a source compliant with the following: Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV).
  • Page 9: Communicate With The Module

    DeviceNet ArmorBlock™ Network Powered 16-input Module Refer to Cordsets and Field Attachables, publication M117-CA502A, or visit the Connection Devices website, http://www.ab.com/connectionsystems. ATTENTION: Make sure all connectors and caps are securely tightened to properly seal the connections against leaks and maintain IP enclosure type requirements.
  • Page 10: Interpret Status Indicators

    10 DeviceNet ArmorBlock™ Network Powered 16-input Module Interpret Status Indicators This module has the following indicators: • Network and module status indicators for DeviceNet • Auxiliary power indicator • Individual I/O status indicators for inputs and outputs 1732D-IBDPM12MND Network Module status status indicator...
  • Page 11 DeviceNet ArmorBlock™ Network Powered 16-input Module Indicator Status for Modules Status Description Module status No power applied to the device. Green Device is online and has one or more I/O connections in established state. Flashing green Device needs commissioning due to missing, incomplete, or incorrect configuration.
  • Page 12: Specifications

    12 DeviceNet ArmorBlock™ Network Powered 16-input Module Specifications General Specifications Attribute Value Number of inputs Input type 61131-2 Type 3 compatible Off-state input voltage, max 5V DC On-state input voltage, min 11V DC On-state input voltage, nom 24V DC On-state input voltage, max 25V DC Sensor source voltage, min 11V DC Sensor source voltage, max 25V DC...
  • Page 13 DeviceNet ArmorBlock™ Network Powered 16-input Module Input Off-to-On or On-to-Off delay is time from a valid input signal to recognition by the module. Use this conductor category information for planning conductor routing as described in Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Refer to Connection Systems, publication C116-CA508.
  • Page 14 14 DeviceNet ArmorBlock™ Network Powered 16-input Module Environmental Specifications Attribute Value Surge transient immunity IEC 61000-4-5: ±1 kV line-line (DM) and ±2 kV line-earth (CM) on signal ports ±2 kV line-earth (CM) on communication ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz Emissions CISPR 11:...
  • Page 15 DeviceNet ArmorBlock™ Network Powered 16-input Module Notes: Publication 1732D-IN007B-EN-E - November 2011...
  • Page 16 RA-DU002, available at http://www.rockwellautomation.com/literature/. Allen-Bradley, Rockwell Automation, ArmorBlock, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1732D-IN007B-EN-E - November 2011...

This manual is also suitable for:

Armorblock series1732d-ibdpm12mnd

Table of Contents