Installation Instructions ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B (Cat. No. 1792D-CB12JP and -CB18JP) CB18JP CB12JP 42273 This version of the ArmorBlock MaXum™ cable base lets you provide power to outputs using DeviceNet™ power. No additional auxiliary power cabling is needed.
Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: • Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1 •...
Page 3
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Powering Outputs Using DeviceNet Power You can power some output devices from the DeviceNet network. The application must allow the voltage to remain within the DeviceNet specification limits of 11-25V dc. Most actuators need to be powered by a separate power supply.
Page 4
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Noise or Transient Protection The typical actuators used in DeviceNet control systems utilize inductive coils that generate transients when de-energized. Each ArmorBlock MaXum output contains a diode which is across the load device coil.
Page 5
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Mount the Cable Base The cable base can be mounted either vertically or horizontally, using 3 screws. Cable bases accommodate 4 or 8 connector ArmorBlock MaXum modules. You must allow additional space for installation of 8 connector ArmorBlock MaXum modules.
Page 6
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B A mounting illustration for the 1792D-CB18JP is below. 1792D-CB18JP 1.90in. 48.18mm 2.70in. 68.5mm 0.64in. 16.25mm 0.26in. 6.5mm 1.42in. 36mm 8.23in. 209mm 4.21in. 8 connector 6.10in 107mm module 155mm 4 connector When module installing a...
Page 7
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Attach the Module Make sure you properly align the screws to IMPORTANT complete the connections between the module contacts and the cable contacts cafeteria. 1. Position the module over the mounted cable base. Align the three captive screws in the module with the accepting receptacles in the base.
Page 8
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B The 1792D-CB18JP module is shown below. Screws must be aligned properly to complete contact connections. Contact connections 42276 ArmorBlock MaXum I/O modules are described in the following publications: • 1792D series of ArmorBlock MaXum Installation Instructions •...
Page 9
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Attach the Cables (1792D-CB12JP) 1. Attach your network cable to the connector. Note: The network cable drops straight down away from the module. 2. Attach your I/O cables. Note: I/O cables drop at a 45 degree angle because of the pin settings, if you use a right angle connector.
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Attach the Cables (1792D-CB18JP) 1. Attach your network cables to the connectors. 2. Attach your I/O cables. I/O cable with a right angle connector 5 pin DeviceNet Out connector 5 pin DeviceNet In connector 41876 Pin 1 Drain...
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Hazardous Location Approval The following information applies only to products marked with Hazardous Location Approval, when operating in hazardous locations: Products marked “CL I, DIV 2, GP A, B, C, D” are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only.
Page 12
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B When used in a Class I, Division 2, hazardous WARNING location, this equipment must be mounted in a suitable enclosure with proper wiring method that complies with the governing electrical codes. Les informations suivantes ne concernent que les produits marqués pour une utilisation en environnements dangereux : Les produits marqués «...
Page 13
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B AVERTISSEMENT Utiliser des fils d’alimentation qui conviennent à une température de 30°C au-dessus de la température ambiante. Pour une utilisation en environnement de classe i, AVERTISSEMENT division 2 dangereux, cet equipement doit etre monte dans un boitier avec un cablage approprie conforme aux normes electriques en vigueur.
Page 14
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Notes: Publication 1792D-IN001B-EN-P - September 2000...
Page 15
ArmorBlock MaXum I/O Cable Bases DeviceNet Powered Outputs Series B Notes: Publication 1792D-IN001B-EN-P - September 2000...