Commercial Condensing Gas-Fired Water Boiler — Boiler Manual
Control operation and setup
Figure 64
control settings available in BASIC MODE (see Advanced Manual for ADVANCED MODE settings)
ni
TM
Boiler Model
Control Type
High Altitude
LP GAS
Manual Reset High Limit Temp
WWSD Temp
Adjust Outdoor
Circulator Exercising
Freeze Protect Circs
Reset Factory Default
Inputs Assigned (non-selectable)
System Type
Target Mod Sensor (non-selectable)
Target Adjust (non-selectable)
Supply Max
Supply Min (not available for DHW) *
OD Reset Max (or Volts for Max) *
OD Reset Min (or Volts for Min) *
Boost Time *
Figure 65
System types available in BASIC MODE (each option shown with factory settings)
8-Character
Abbreviation
Fan-coil
FAN-COIL
Finned Tube
FIN BASE
Baseboard
Cast Iron Baseboard
IRONBASE
Cast Iron Radiators
RADIATOR
Radiant - slab on grade
RAD SLAB
Radiant - thin slab
RAD SLAB
RADFLOOR
(staple up)
RADFLOOR
(sleeper system)
Domestic Hot Water
DOMESTIC
XXXXXXXX
(user input)
Part number 550-100-250/0819
Inputs Assigned (non-selectable)
System Type
Target Mod Sensor (non-selectable)
Target Adjust (non-selectable)
Supply Max
Supply Min (not available for DHW) *
OD Reset Max (or Volts for Max) *
OD Reset Min (or Volts for Min) *
Boost Time *
Inputs Assigned (non-selectable)
System Type
Target Mod Sensor (non-selectable)
Target Adjust (non-selectable)
Supply Max
Supply Min (not available for DHW) *
OD Reset Max (or Volts for Max) *
OD Reset Min (or Volts for Min) *
Boost Time *
* These items only appear in the menus if Target Adjust is active.
3-Character
Supply Max
Abbreviation
°F
FCL
180
FTB
180
CIB
180
CIR
180
RSG
120
RTS
140
RSU
160
RAF
140
DHW
180
first three of
180
user input
(continued)
Priority 1, 2 or 3
Source (TT1 or 0-10v)
AUX PUMP/OUTPUT
Off
Priority 1, 2 or 3
AUX PUMP/OUTPUT
Off
Diagnostics menu
See Figure 72, page 79 for details.
See Figure 77, page 84 for details.
See Figure 77, page 84 for details.
OD Reset
Supply
OD Reset
Min °F
Min °F
Max °F
0
140
70
0
130
70
0
120
70
0
120
70
0
80
70
0
80
70
0
90
70
0
90
70
N/A
N/A
N/A
0
70
70
Run AUX
Run
PUMP/
Boiler Pump
OUTPUT
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES