TriangleTube Prestige Solo PT 60 Installation & Maintenance Instructions Manual

Carbon monoxide (co) detector kit

Advertisement

Quick Links

https://triangletube.com/professional-
resources/video-library/
Prestige Solo PT 60-110-175-250-399
Prestige Excellence PTE 110
Prestige Solo PA 80-110-155-175-250-299-399
Prestige Excellence PEA 110
Carbon Monoxide (CO) Detector Kit - Installation & Maintenance Instructions
Installation shall be performed by a qualified installer, service agency, or the gas supplier.
CONTENTS
1 - Definitions ............................................................................ 1
2 - Purpose ................................................................................ 1
3 - Applicability ......................................................................... 1
5 - Defining the Installation Location................................... 2
5.1
5.2
5.3
6 - Kit Installation .....................................................................3
6.1
Tools and material ...............................................................................3

1 - Definitions

The following terms and symbols are used throughout
this manual to bring attention to the presence of potential
hazards or to important information.
Indicates the presence of a hazardous situation
which, if ignored, will result in substantial
property damage, serious injury, or death.
Indicates a potentially hazardous situation
which, if ignored, can result in substantial
property damage, serious injury, or death.
Indicates special instructions on installation,
operation or maintenance, which are important
to the equipment but not related to personal
—
This symbol indicates that you need to
make a picture (with your phone or other)
for later reporting.
Pub. date: 26/02/25
(Fig. 2) .........................................2
) ......................................................2
) .............................................................2
) .....................................3
• DANGER
• WARNING
NOTICE
injury hazards.
These instructions shall be kept with the appliance literature for future reference.
• WARNING
6.2
Base Box Installation ..........................................................................3
6.3
Wall Installation .....................................................................................3
6.4
Kit Connection .......................................................................................4
6.5
Functional Check .................................................................................9
7 - CO Detector Operation ..................................................... 9
7.1
Alarm features ..................................................................................... 10
7.2
Periodic Inspections and Maintenance ..................................... 10
7.3
Battery Replacement ........................................................................ 10
7.4
Problems and Solutions .....................................................................11
7.5
Follow-on Tasks ....................................................................................11
8 - Record and Report ............................................................11
8.1
Recording ...............................................................................................11
8.2
Labels .......................................................................................................11
8.3
Reporting .............................................................................................. 12
9 - Informing the User ...........................................................12
™
This symbol indicates that an instructional
"HOW TO" video is available from Triangle
Tube's website. A direct link to the library
is available at the top left corner of the
front cover.

2 - Purpose

The installation of this kit (see Fig. 1 for details) close
to the boiler improves end user safety with respect to
Carbon Monoxide (CO) hazards.
This Carbon Monoxide (CO) Detector kit is
provided as an additional level of safety for
the end user. It substitutes in no way for the
mandatory CO detectors to be installed by the
end user in the mechanical room where the
boiler is located and in the area outside each

3 - Applicability

Prestige Solo PT 60-110-175-250-399
Prestige Excellence PTE 110
Prestige Solo PA 80-110-155-175-250-299-399
Prestige Excellence PEA 110.
A1011258 - 664A0770 • A
Triangle Tube
1240 Forest Parkway, Suite 100,
West Deptford NJ 08066
Tel: (856) 228 8881 - Fax: (856) 228 3584
E-mail:
techsupport@triangletube.com
• WARNING
sleeping area.
PARKIT520 - PARKIT521
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Prestige Solo PT 60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TriangleTube Prestige Solo PT 60

  • Page 1: Table Of Contents

    Tel: (856) 228 8881 - Fax: (856) 228 3584 https://triangletube.com/professional- E-mail: techsupport@triangletube.com resources/video-library/ Prestige Solo PT 60-110-175-250-399 Prestige Excellence PTE 110 Prestige Solo PA 80-110-155-175-250-299-399 Prestige Excellence PEA 110 Carbon Monoxide (CO) Detector Kit - Installation & Maintenance Instructions • WARNING Installation shall be performed by a qualified installer, service agency, or the gas supplier.
  • Page 2: Kit Reference & Contents (Fig. 2)

    CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 5.1 Dimensions and weight ( 4 - Kit Reference & Contents (Fig. 1) Fig. 1 Kit part number : PARKIT520 (US) / PARKIT521 (CANADA) The kit weighs around 3 Lbs [1.5 kg]. In addition, it is 1.
  • Page 3: On A Wall Adjacent To The Boiler ( Fig. 3 )

    CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 5.3 On a Wall Adjacent to the Boiler ( Fig. 2 NOTICE If installation on the boiler is not possible, the CO If placing the CO detector box on top of the detector base box (C) must be installed on a wall using boiler, make sure that: the two eyelets (A), and screws and anchors adapted to...
  • Page 4: Kit Connection

    CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 6.4 Kit Connection NOTICE 5. Remove the front panel. See illustrations below. The following procedures apply to both PT and PA boiler types. Some illustrations represent one type or the other BUT the principles PT Boiler of installation are identical.
  • Page 5 CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 6.4.2 Power Supply Connection 5. Route the free harness end (5) on the right side of the boiler, and down to the front. NOTICE 6. Route the flex armored power supply cable of CO detector assembly (1) along the right side of the boiler The illustration below shows a PA boiler type.
  • Page 6 CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS Prestige Solo Internal Wiring NOTICE ACV MAX ACV MAX Display Control Board Cascade Slave Reference the wiring diagram label at the back of the front panel for a complete view. Cascade Slave Flame Flame NOTICE...
  • Page 7 CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS NOTICE ACV MAX ACV MAX Display Control Board Cascade Reference the wiring diagram label at the back of the front Slave panel for a complete view. Cascade Slave NOTICE Flame Flame CH Pump P4 Pump Any accessory connected to the Manual Reset terminals of the CH Pump...
  • Page 8 CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS NOTICE TriMax TriMax Prestige Solo Internal Wiring Reference the wiring diagram label at the back Display Module Control Module of the front panel for a complete view. Flue Temperature Sensor Gas Valve Gas Valve (Solo 399 only) (All except Solo 399)
  • Page 9: Functional Check

    CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 4. If necessary, adjust the position of cable gland on the NOTICE cable, so that the length of cable inside the boiler is sufficient to connect to the signal harness terminal block. When the CO detector alarm operates, 5.
  • Page 10: Alarm Features

    CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 7.1 Alarm features 6. If the detector was silenced by depressing the silence button, after the 4-minute silence cycle, the CO detector re-evaluates CO levels and responds accordingly : 7.1.1 Lights and Sounds - Normal Operation ♦...
  • Page 11: Problems And Solutions

    CO DETECTOR KIT - INSTALLATION AND MAINTENANCE INSTRUCTIONS 7.5 Follow-on Tasks 3. Install battery close battery compartment (1). — Make pictures of the installation once it 4. Push and hold the test button (2) on the CO detector is completed (CO detector assembly and cover until you hear an acknowledge chirp and the cable connections).
  • Page 12: Reporting

    Operation and Safety 8.3 Reporting Instructions for the User (See below). 1. Connect to the portal (https://r2rportal.triangletube.com) 2. Inform the user that this CO detector kit does not substitute for the mandatory installation of CO detectors in the living areas and in the mechanical room where the boiler is installed.