3.2

Assembly

3.2.1

Mounting the functional unit

Functional unit
Mark the internal contour (280 x 150 mm) of the installation frame on
the cladding panel.
Use a keyhole saw to cut the cladding panel out along the dimen-
sion line.
Clad the remaining pre-wall according to the Viega specifications.
Dispose of the cover of the revision shaft.
Align the installation frame centrally over the revision shaft.
A length of double-faced adhesive tape is provided at one side of
the installation frame.
Stick the installation frame onto the cladding panel.
Adjust the chrome-plated internal frame to the respective wall cov-
ering.
The upper edge of the chrome-plated internal frame must be flush
with the wall tile.
Setting range 5–18 mm.
INFO! Make allowance for the thickness of the tile adhesive!
Handling