Page 1
Urinal module Instructions for Use for "Joly" and "Visit" (Keramag) urinal, connection of the Visign equipment set (manual and touchless flush actuation) Model Year built: 8127.3 from 03/2009 en_INT...
Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Standards and regulations Intended use 2.2.1 Areas of use Product description 2.3.1 Overview 2.3.2 Compatible components 2.3.3 Sound protection 2.3.4 Technical data Handling...
This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.
2 Product information Standards and regulations The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your viega.com/standards . country at Regulations from section: Sound protection Scope / Notice...
Product information Product description 2.3.1 Overview Fig. 1: Components 1 - urinal installation set 2 - suction moulded piece 3 - connection for Keramag "Joly" and "Visit" 2.3.2 Compatible components The urinal module is compatible with the urinals "Joly" and "Visit" by Keramag.
Product information Product Name Model Flush plate Visign for 8333.2 Style 13 Flush plate Visign for 8334.2 Style 14 Visign for More Flush plate Visign for 8352.2 More 100 Flush plate Visign for 8353.2 More 102 Flush plate Visign for 8355.2 More 103 Flush plate Visign for...
Handling 3 Handling Assembly information 3.1.1 Mounting conditions Construction height With the construction height, the marked height of the upper edge of the finished floor must be observed. Actuation The actuation takes place via manual flush actuation, connection of the Visign equipment set.
Page 10
Handling Push the slot nut in slightly. Turn by 90°. ð The slot nut is secured in the Steptec rail. Align the height of the module. Tighten the slot nut with a ring spanner (SW 17). Tighten the other slot nuts in the same way. ð...
Page 11
Handling Make water connection. Check height settings. In addition, observe the following details. Keramag 'Joly' Urinal module 11 from 15...
Page 12
Handling A - The size results from Urinal module 12 from 15...
Page 13
Handling A - The size results from Keramag 'Visit' Urinal module 13 from 15...
Page 14
Handling A - The size results from Urinal module 14 from 15...
Handling A - The size results from 3.2.2 Rounding off jobs Single clad pre-wall: Clad with 12.5 mm wide IFGP or 12 mm wide Aqua-KS cladding panels. When doing so, make sure that no abutting edges converge. Grout the abutting edges and joints with a suitable filler. Observe the instruction manual for the cladding panels for more information.