Instruction References
6.1 High-level Instructions Used for EtherNet/IP Control
6.1.1 Information Acquisition of EtherNet/IP (F465 ETSTAT)
Instruction format
R0
(Note 1): The figure above shows the case of specifying a communication unit slot number (Ethernet communication
= K100) using F469 UNITSEL instruction.
(Note 2): By copying and pasting the following text in the instruction list box of FPWIN GR7, the operation part of the
above program can be input.
ETSTAT "EIP" "ALL" DT0
List of operands
Operand
Description
Specify the type to be read with the starting address or a character constant.
S1
S2
Specify the target to be read with the starting address or a character constant.
D
Specify the starting address of destination.
Available devices (
Memory device
Operand
WX WY WR WL SV EV
●
S1
●
S2
D
6-2
●
: Available)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
F469
UNITSEL
F465
"EIP"
ETSTAT
S1
DT LD I
SWR SDT
●
●
●
●
●
●
●
●
●
K100
K1
"ALL"
DT0
S2
D
Constant
Index
modifier
K
H
M
●
●
●
●
●