1. Turn the stop cock valve ON by rotating the lever clockwise until it is in
line with the hose.
2. Wipe up any spills. Close the door to secure the appliance.
3. Initiate the filter flush program by pressing [Start] (See section C - 1).
4. Reset the filter counter, see section C - 2.
5. Dispose of the used cartridge and packaging thoughtfully.
1
ROTATE
2
PULL DOWN
Air Inlet Filter
The Zenith HydroTap air filter is conveniently located on the outside of the
condenser. The filter screen is a sliding fit in the plastic housing on the right
hands side of the under sink unit. The screen may be removed for cleaning,
by sliding it forward. This needs to be inspected at least quarterly, cleaned
and replaced if damaged.
Note: For best performance the unit should only be operated with a clean
air filter screen, correctly fitted in place. Maintain, at least, a 50mm air gap
in front of the screen at all times. Take care not to allow cloths or other soft
materials to accidentally block the air inlet.
802254NZ - HT BC User Guide 10.18 v3.02
Filter Maintenance
1
INSERT
ROTATE
2
Warning: If the Zenith
HydroTap is switched off for
a long period of time (e.g.
longer than a weekend),
run water through the
chilled water outlet for at
least 5 minutes before
consumption.
Page 25 of 28