Download Print this page

Zenith HydroTap G4 Series User Manual page 21

Advertisement

LCD Screen operation - Section G
Energy Modes
This mode allows the HydroTap to Go into Energy Saving mode. There are
two options available: 'Sleep' mode and 'ON/OFF' mode.
In Sleep Mode the unit will Go to "Sleep" after a 2hr period of inactivity.
The Boiling water will gradually drop to either 68°C or room temp, as shown
in the table below and the Chilled water will be ON or OFF.
When the period of inactivity passes, the home screen status window will
show "Sleep Mode".
Sleep Mode
2 Hours-> 68°C
2 Hours-> OFF
Lux Sensor->68°C
Lux Sensor-> OFF
Lux or 2 Hr-> 68°C
Lux or 2 Hr-> OFF
Disable
Lux (Light) Sensor Calibration: (Not for Elite tap)
It is recommended to recalibrate the Lux (Light) Sensor after selecting any of
the 4 Lux sensor options from the sleep mode menu. Before commencing,
ensure there are 'Normal to Dim' (Not Dark) operating light conditions.
Note: Refer to section C5 on Page 14 for calibration procedure
802254NZ - HT BC User Guide 10.18 v3.02
To activate the sleep mode:
1. Press [MENU] button for main
menu.
2. Press [Setting] button.
3. Press [Energy Modes] button.
4. Press [Sleep Modes] button then in
the next screen, use the up and down
arrows to select one of the 7 options, as
shown in the table below.
Light
Time
Level
Delay
N/A
2 Hr
N/A
2 Hr
Dark
N/A
Dark
N/A
Dark
2 Hr
Dark
2 Hr
N/A
N/A
State Boiler Chiller
Sleep
68°C
OFF
OFF
Sleep
68°C
OFF
OFF
Sleep
68°C
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
Page 21 of 28