4.4.c - Filling (for the version with external
pump) (Fig. 5a)
On request, the pump can be installed outside rather
than inside the machine acting as follows:
Position the pump away from heat sources
and water jets. The support surface must
be horizontal and able to support the size
and weight of the pump.
-
Position the pump (1) underneath the machine at a
distance of not more than .... cm keeping a distance
between the pump and the external walls of at least
5 cm to prevent transmission of vibration and allow
proper air circulation.
-
Connect the tube (2) leading from the machine to
the pump delivery union (1).
-
Connect the pipe (3) provided to the pump intake
union and the other end to a softener (4) with the
impurity filter (5) between them.
-
Before the softener (4), install a shutter valve (6) to
separate the water system from the machine.
-
Connect the pump connector (7) to the preset con-
nector (8) leading from the machine.
EN
To install, operate and service the softener,
see the relevant instruction manual.