SUN2000-(25KTL, 30KTL)-US
User Manual
When connecting the SUN2000 output power cable, you can choose whether to connect
the neutral wire or not according to the local national regulations and installation
specifications.
AC output terminals must be parallel.
When installing the AC output power cable, the torque must not exceed 6 N· m. Otherwise,
the AC terminal block may be damaged.
Ensure that the AC output power cable is securely connected. Otherwise, the SUN2000
may fail to operate or the terminal block may be damaged after the SUN2000 operates.
Sufficient slack should be provided in the PE cable to ensure that the last cable bearing the
force is the PE cable when the AC output power cable bears pulling force due to force
majeure.
Figure 5-12 Connecting AC output power cables
Issue 09 (2019-06-30)
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connections
60