Figure 5-9 Stripping an AC output power cable
Step 3 Connect the SUN2000 AC output power cable to the AC terminal block and secure the cable
to a torque of 5 N· m.
Issue 09 (2019-06-30)
Wrap the wire crimping area with heat shrink tubing or PVC insulation tape. If heat shrink tubing is used,
wrap the cable with the heat shrink tubing and then crimp the OT terminal.