Parameter
Active power
percentage derating
Reactive power
output at night
Power factor
Reactive power
compensation (Q/S)
Night-time reactive
power compensation
(Q/S)
Overfrequency
derating
Trigger frequency of
over frequency
derating
Quit frequency of
over frequency
derating
Cutoff frequency of
overfrequency
derating
Cutoff power of
overfrequency
derating
Recovery gradient
of over frequency
derating
Issue 09 (2019-06-30)
Description
Adjusts the active power output of the
SUN2000 to a percentage.
In some specific application scenarios,
a power grid company requires that
the SUN2000 can perform reactive
power compensation at night to ensure
that the power factor of the local
power grid meets requirements.
Adjusts the SUN2000 power factor.
Adjusts the SUN2000 output reactive
power.
If Reactive power output at night is
enabled, no PV input exists, and no
remote scheduling instruction is
delivered, the SUN2000 responds to
this command.
If this parameter is enabled, the active
power of the inverter will be derated
according to a certain slope when the
grid frequency exceeds the value that
triggers overfrequency derating.
The standards of certain countries and
regions require that the output active
power of the SUN2000 be derated
when the grid frequency exceeds a
certain value.
Specifies the frequency threshold for
exiting overfrequency derating.
Specifies the frequency threshold for
cutting off overfrequency derating.
Specifies the power threshold for
cutting off overfrequency derating.
Specifies the power recovery gradient
for overfrequency derating.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Unit
Value Range
%
[0, 100]
If this parameter is set to 100,
the SUN2000 delivers power
output based on the maximum
output power.
N/A
Disable
Enable
(–1.000, –0.800]U[0.800,
N/A
1.000]
N/A
[-0.6, 0.6]
N/A
[-0.6, 0.6]
N/A
Disable
Enable
Hz
When the output frequency
is 50 Hz, the value range is
45.00–55.00 Hz.
When the output frequency
is 60 Hz, the value range is
55.00–65.00 Hz.
Hz
Hz
(%)
[0, 100]
%/min
[1, 6000]
100