No.
Parameter
Description
3
RCD
RCD refers to the
enhancing
residual current of the
SUN2000 to the
ground. To ensure
device security and
personal safety, RCD
should comply with
the standard. If an AC
switch with a residual
current detection
function is installed
outside the SUN2000,
this function should
be enabled to reduce
the residual current
generated during
SUN2000 running,
thereby preventing the
AC switch from
misoperations.
Reactive
In some specific
4
power
application scenarios,
output at
a power grid company
night
requires that the
SUN2000 can
perform reactive
power compensation
at night to ensure that
the power factor of
the local power grid
meets requirements.
Issue 01 (2018-09-30)
Unit
Default
Value
N/A
Disable
N/A
Disable
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Value Range
Remarks
Disable
N/A
Enable
This parameter is
Disable
configurable only
Enable
when Isolation is set
to Input
ungrounded, with a
transformer.