Figure 7-4 Feature parameters (advanced user)
----End
Parameter List
No.
Parameter
1
MPPT
multi-peak
scanning
2
MPPT
multi-peak
scanning
interval
Issue 01 (2018-09-30)
Description
When the SUN2000 is
used in scenarios
where PV strings are
obviously shaded,
enable this function.
Then the SUN2000
will perform MPPT
scanning at regular
intervals to locate the
maximum power.
Specifies the MPPT
multi-peak scanning
interval.
Copyright © Huawei Technologies Co., Ltd.
Unit
Default
Value
N/A
Disable
min
15
7 Man-Machine Interactions
Value Range
Remarks
Disable
The scanning
interval is set by
Enable
MPPT multi-peak
scanning interval.
[5, 30]
This parameter is
displayed only when
MPPT multi-peak
scanning is set to
Enable.