Operating Instructions; Protection Against Electrostatic Discharges - ABB VA Master FAM540 Commissioning Instructions

Metal cone variable area flowmeter
Hide thumbs Also See for VA Master FAM540:
Table of Contents

Advertisement

Table 5: Analog indicator without alarm signaling unit
Model FAM54xAx
Type of protection: constructional safety, dust explosion protection
Order
Labeling
1)
code
A4, A9,
ATEX:
B1
II 1/2 G c II T6...T1
II 2D c T85 °C to T
medium
II 2D Ex tb IIIC T85 ˚C... T
IECEx:
Ex tb IIIC T85 °C ... T
Change from one to two columns
2.4

Operating instructions

2.4.1

Protection against electrostatic discharges

DANGER
Risk of explosion!
The painted surface of the device can store electrostatic
charges. As a result, the housing can form an ignition source
due to electrostatic discharges in the following conditions:
— The device is operated in environments with a relative
humidity of ≤ 30 %.
— This painted surface of the device is therefore relatively
free from impurities such as dirt, dust or oil.
The instructions on avoiding the ignition of hazardous areas
due to electrostatic discharges in accordance with the
EN TR50404 and IEC 60079-32-1 standards must be
observed!
14 CI/FAM540-EN Rev. B | VA Master FAM540
Terminals Electrical
n.a.
Db
medium
Db
medium
T
amb
values
-20 °C ... (-50 °C ... )
n.a
70 °C
70 °C
70 °C
70 °C
70 °C
70 °C
Instructions on cleaning
The painted surface of the device may be cleaned only using a
moist cloth.
Temp.
T
Insula-
medium
class
Maximum
tion
T1
440 °C
yes
T2
290 °C
yes
T3
190 °C
yes
T4
130 °C
yes
T5
95 °C
yes
T6
80°C
yes
Heating
jacket
yes
yes
yes
yes
yes
yes