8

Operation

8.1

Operating instructions

Observe the following points when operating the device:
— Aggressive media may result in corrosion and abrasion of
the parts that come into contact with the medium. As a
result, pressurized media may escape prematurely.
— Wear to the flange gasket or process connection gaskets
(e.g., aseptic threaded pipe connections, Tri-Clamp, etc.)
may enable a pressurized medium to escape.
— When using internal flat gaskets, these can become
embrittled through CIP/SIP processes.
If there is a chance that safe operation is no longer possible,
take the device out of operation and secure it against
unintended startup.
36 CI/FAM540-EN Rev. B | VA Master FAM540
9

Maintenance

9.1

Safety instructions

DANGER
Danger of explosion if the device is operated with the
transmitter housing open!
Before opening the transmitter housing, bear in mind the
following:
— Check that a valid fire permit is available.
— Make sure that there is no explosion hazard.
— Before opening the device, switch off the power supply
and wait for t > 2 minutes.
WARNING
Risk of injury due to live parts!
When the housing is open, contact protection is not provided
and EMC protection is limited.
Before opening the housing, switch off the power supply.
CAUTION
Risk of burns due to hot measuring media.
The device surface temperature may exceed 70 °C (158 °F),
depending on the measuring medium temperature!
Before starting work on the device, make sure that it has
cooled sufficiently.
NOTE
Damage to components!
The electronic components of the printed circuit board can
be damaged by static electricity (observe ESD guidelines).
Make sure that the static electricity in your body is
discharged before touching electronic components.
NOTE
For detailed information on the maintenance of the device,
consult the associated operating instructions (OI)!

10 Specifications

NOTE
The detailed device data sheet is available in the download
area at www.abb.com/flow.