Deleting the saved settings (returning to factory settings)
Returning all settings to factory settings
Multiplex Trio E fitting, electronic mixing unit
Operating status
OFF
Action
n
n
n
n
n
n
Result
You have saved the water volume currently in
the tub and the mean temperature of the
flown-in water to the selected memory space.
The water inlet stops.
The saved temperature corresponds to the actual tempera‐
ture of the bath water and can significantly deviate from the
target temperature selected last.
Operating status
OFF
Action
n
n
n
Result
You have reset the selected memory space to
factory settings (also see
„Factory settings" on page 25).
The water inlet stops.
Use this function to reset all settings to delivery state (see
3.3.1 „Factory settings" on page 25).
Briefly press the operating element (1 x, 2
x or 3 x) to select the desired memory
space.
Turn the control element to adjust the
water temperature.
Turn clockwise ⇨ for warmer water; turn
anti-clockwise ⇨ for colder water.
Keep the control element pressed and turn
it to adjust the strength of the water
stream.
Let the water flow in up to the desired
filling level.
Keep the control element pressed until the
illuminated ring emits purple light.
Release the control element.
Briefly press the operating element (1 x, 2
x or 3 x) to select the desired memory
space.
Keep the control element pressed until the
illuminated ring emits dark blue light.
Release the control element.