Sony Trinitron PVM-20M4A Operating Instructions Manual page 5

Color video monitor
Hide thumbs Also See for Trinitron PVM-20M4A:
Table of Contents

Advertisement

Available languages

Available languages

Functions
Underscan mode
The signal normally scanned outside of the screen can
be monitored in the underscan mode.
Note
When the monitor is in the underscan mode, the dark
RGB scanning lines may appear on the top edge of the
screen. These are caused by an internal test signal,
rather than the input signal.
Horizontal/vertical delay mode
The horizontal and vertical sync signals can be
checked simultaneously in the H/V delay mode.
Auto/manual degaussing
Degaussing of the screen can be performed
automatically when the power is turned on, or
manually by pressing the DEGAUSS button.
You can set the delay time of auto degaussing to start
working after the power is turned on. (DEGAUSS
DELAY menu)
On-screen menus
You can set color temperature, CHROMA SET UP,
and other settings by using the on-screen menus.
Five menu languages
You can select the menu language from among five
languages on the menu.
SDI (Serial Digital Interface) Kit
By using the following optional SDI Kits, the monitor
can display SMPTE 259M 4:2:2 serial digital signal
from a digital VCR. (ex. Sony 4:2:2 VCR)
– BKM-101C: Component SDI Kit (for video)
– BKM-102:
Component SDI Kit (for audio)
Note
When the serial number of the BKM-101C you want to
connect is less than 2,010,000, an optional connecting
harness (part no. 1-900-230-35) will be required.
Serial Remote Interface Kit
By using the optional BKM-103 Serial Remote
Interface Kit, the monitor can be controlled from
personal computers via the RS-422A serial interface.
EIA 19-inch rack mount kit available
Use a suitable kit when rack mounting.
Europe
Any other area
ATTENTION – When the product is installed in
a rack:
a) Elevated operating ambient temperature
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature
of the rack environment may be greater than
room ambient. Therefore, consideration should
be given to installing the equipment in an
environment compatible with the
manufacturer's maximum rated ambient
temperature (Tmra).
b) Reduced air flow
Installation of the equipment in a rack should
be such that the amount of air flow required for
safe operation of the equipment is not
compromised.
c) Mechanical loading
Mounting of the equipment in the rack should
be such that a hazardous condition is not
achieved due to uneven mechanical loading.
d) Circuit overloading
Consideration should be given to the
connection of the equipment to the supply
circuit and the effect that overloading of circuits
might have on overcurrent protection and
supply wiring. Appropriate consideration of
equipment nameplate ratings should be used
when addressing this concern.
e) Reliable earthing
Reliable earthing of rack-mounted equipment
should be maintained. Particular attention
should be given to supply connections other
than direct connections to the branch circuit
(e.g., use of power strips).
MB-502C (14-inches) /
SLR-103C (20-inches)
MB-502B (14-inches) /
SLR-103A (20-inches)
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents