XX
REFILL
XXX
(-)
DONE
(+)
SPRAY OZ/M: XX.X
(-)
DONE
(+)
DILUTE OZ/M: XX.X
(-)
DONE
(+)
CALIBRATE FLOW?
NO
YES
BREW COUNTERS?
NO
YES
SET RECIPES TEMPS
NO
YES
ENTER ASSET #
NO
YES
ENTER SERVICE #
NO
YES
SERVICE TOOLS
NO
YES
FACTORY DEFAULTS
NO
YES
This function allows the operator to adjust the sensitivity of the refill circuit. This is
mainly a troubleshooting feature. Water in different geographical locations can have
different conductivities. By adjusting the sensitivity of the refill circuit, this will allow the
brewer to operate under various water conditions.
This function allows the operator to view or enter the actual flow rate coming out of each
sprayhead. This is Not used to control the actual flow rate, but to tell the internal proces-
sor how fast the water is flowing.
This function allows the operator to view or to enter the actual flow rate coming out of
the dilution nozzle. This is not used to control the actual flow rate, but to tell the internal
processor how fast the water is flowing.
This function allows the operator to test and enter the actual flow rate of the
sprayhead(s) and the bypass/dilution for each side of the brewer by dispensing each
separately for one minute. The volumes are then entered into the brewer.
This function allows the operator to track the total number of brew cycles completed, as
well as the number of batches brewed using each of the brew buttons. There are (up to)
three resettable counters, and one life counter that is not resettable.
This function allows the operator to set separate temperatures for each selected recipe.
This function allows the operator to enter the machine's asset number. This can be use-
ful for tracking the usage or service of an individual machine within a group.
This function allows the operator to enter in the telephone number to call if service is
needed. The service number will be displayed anytime there is a fault message dis-
played.
(For Authorized Service Personel Only)
This function allows the testing of individual components and the ability to check
switches for proper function. This function also tests the funnel sensor coil's frequency
(diagnostic tool for troubleshooting purposes only).
Refer to Service Manual for in depth procedures.
This function allows the operator to erase all of the previously entered recipes and ad
messages. Factory-set default values will replace All previous settings.