Appendix A - 8520C-36 Signal Selector
#5 ENG COOD: CHANNEL 25
#4 FWD COMP: CHANNEL 24
#1 PROP: CHANNEL 21
co.
Move cable P/N 11517 to connector labeled "29-36" on 8520C-36 and move magnetic
pickup cable P/N 10808 to channel D on 8520C-36. Repeat steps f through cl, using the
following values:
PICKUP: CHANNEL <D>
#A1: CHANNEL 35
#A2: CHANNEL 34
#3 ENG. ACC: CHANNEL 31
#2 AFT G/B: CHANNEL 30
#5 ENG COOD: CHANNEL 33
#4 FWD COMP: CHANNEL 32
#1 PROP: CHANNEL 29
cp.
To test the 8520C-36 single-channel connectors, make connections as shown in Figure A-
4.
cq.
Press SETUP.
cr.
Key in the following values:
PICKUP: CHANNEL <A>
INPUT: CHANNEL 1
cs.
Press ENTER soft key.
ct.
Wait 10 seconds and press START key.
cu.
Verify that display indicates:
900±1 RPM
0.4±0.04 IPS
275°±10°
cv.
Press STOP key.
cw.
Move magnetic pickup cable P/N 10808 to channel B and Velo cable P/N 11210 to
channel 2 on 8520C-36. Repeat steps cq through cv, but substitute the following values:
PICKUP: CHANNEL <B>
INPUT: CHANNEL 2
cx.
Move magnetic pickup cable P/N 10808 to channel C and Velo cable P/N 11210 to
channel 3 on 8520C-36. Repeat steps cq through cv, but substitute the following values:
PICKUP: CHANNEL <C>
INPUT: CHANNEL 3