Table 5-11. 8520C Signal Selector Tests - Honeywell Chadwick-Helmuth 8500C Maintenance Manual

Balancer/analyzer system
Table of Contents

Advertisement

Table 5-11. 8520C Signal Selector Tests

Problem
5.5.2.3 amplitude, Frequency, and Phase
Accuracy Test
Vibration level, frequency reading, or phase
angle does not meet specifications.
5.5.2.4 Channel Crosstalk Test
Noise signal above .01 IPS is displayed.
Solution
1. Check 8520C harness assembly
(Figure 5-19) for shorted or open
connections which can be caused by loose
or pinched wires, unplugged connectors, or
worn-through insulation.
2. Disconnect 8520C and retest according to
5.5.1.3, "Amplitude, Frequency, and Phase
Accuracy Tests."
3. If 5.5.1.3, "Amplitude Frequency, and
Phase Accuracy Tests, " pass, 8520C is
most likely at fault. Replace 8520C
controller board (Figure 5-19, A1).
1. Disconnect 8520C and retest according to
5.5.1.4, "Noise and Spurious Signals Test."
2. If 5.5.1.4, "Noise and Spurious Signals
Test," passes, 8520C is most likely at fault.
Replace 8520C controller board
(Figure 5-19, A1).
8500C/8500C+ System Maintenance Manual 5-41
Troubleshooting Guide